A
Technical appendix
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
147
A.2
Connection data
A.2.1
General connection data
Nominal voltage
[V DC]
24 ± 15%
Nominal output current
[A]
5.7
Total current consumption
[A]
up to 9.4 (configuration-dependent)
Protection against electric shock
PELV circuit (Protected Extra-Low Voltage)
Protection class to EN60529
IP40 (plug connector inserted or fitted with pro
tective cap)
Mains filter
Integrated
A.2.2
[X1] I/O interface
Signal level
Base on EN 61131-2:2008-04, type 1
Max. cable length
[m]
30
Digital inputs
Nominal voltage (related to 0 V)
[V DC]
24
Maximum permitted input voltage
[V DC]
29
Nominal current per input
[mA]
2 (typical)
Scanning rate
[ms]
1
Reaction time to input
[ms]
2 (typical)
Galvanic isolation
no
Digital outputs
Maximum current per output
[mA]
100
Overload protection
No overload protection (not short-circuit proof )
Only use for switching the digital inputs.
A.2.3
[X1] Logic auxiliary power 24 V OUT [X1.24] GND [X1.25]
Nominal voltage
– Supply via [X9]
– not additionally filter or stabilized
[V DC]
24
Maximum current
[mA]
100
Overload protection
No overload protection
Only use for switching the digital inputs
Содержание CMMO-ST-C5-1-DION