80
d3.49
30460008
CPLD_Filter
Configure the filter in the CPLD.
For 50% duty cycle signal:
0: 125ns
1: 156ns
2: 250ns
3: 313ns
4: 1ms
5: 1.5ms
6: 2ms
7: 4ms
4
0-7
RWS
d3.50
30510110
Enc_ALM
Show the full error state of the Nikon
encoder.
0
0-65535
R
d3.51
26900008
Encoder_Data_Reset
1: Clear the fault state of encoder.
2: Read the full fault state.
3: Clear the fault state and the MT
data.
0
0-255
RW
d3.52
2FF02310
Jog_RPM
Set Jog velocity.
unit: RPM, not savable.
30
-32767-
32768
RW
d3.53
20100110
Din_Polarity
Define the polarity of Din signal, 0:
normal closed; 1: normally open
Bit 0: Din1
Bit 1: Din2
Bit 2: Din3
…
65535
0-65535
RWS
d3.54
20100D10
Dout_Polarity
Define the polarity of Dout signal,
0: normal closed;
1: normally open
Bit 0: Dout1
Bit 1: Dout2
Bit 2: Dout3
...
65535
0-65535
RWS