Commissioning
Filtration Learning System
46
© Festo Didactic
696684
•
Connect analog I/Os of the EduTrainer (3/C) and analog terminal XD3 (6) of the station
with analog I/O data cable (8) or check the connection.
•
Connect the EduTrainer laboratory sockets to the power supply and power supply unit with laboratory
cables (9 - 4 mm safety plug red = + / blue = -) or check the connection.
•
Connect your PC or operator unit with a network cable to the PLC controller (not shown) or check the
connection.
Figure 26: Cable connection MPS
PA Station - EduTrainer Universal
without
power supply
Legend
1
I/O connection board MPS-PA station
2
Power supply unit 24 V DC, 4.5 A
3
Edutrainer Universal with PLC
4
Control panel
5
I/O terminal SysLink
6
Analog terminal
7
SysLink I/O data cable, parallel (034031)
8
Analog cable, 15-pin, parallel (529141)
9
Laboratory cable with safety laboratory sockets
(red/blue)
10 SysLink I/O data cables, parallel (034031)