![Festo 8079862 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/festo/8079862/8079862_operating-instructions-manual_2284236032.webp)
Setup
Filtration Learning System
32
© Festo Didactic
696684
8.10.2
Float switch, lateral installation
The SG10 float switch for side installation monitors the increasing liquid level in the tank and serves as
overflow protection. As soon as the maximum level is exceeded, the float moves upward with both switches,
the reed contact in the switch housing opens and interrupts the circuit of the pumps. The pumps are
switched off.
Figure 14: Level monitoring with float switch (lateral installation)
8.11
Compressed air supply
As a service unit, a filter control valve with pressure gauge and switch-on valve for compressed air supply is
mounted on a swivel mount. The on-off valve pressurizes and exhausts the connected MPS PA station. The
station accessories included in the station scope of delivery include:
•
Plastic tubing PUN 6x1, 5 m
•
T-plug connector for 6 mm tubing
Figure 15: On-off valve with filter regulator
Attention!
Loud noises are generated when operating the service unit!