6.3.1. [0xBE] ISO 14443-4 T=CL (#)
This command provides the data exchange between a host and the Transponder on ISO 14443-4
layer. It is special designed for easy APDU data exchange.
NOTICE:
The maximum buffer size of the Reader for data exchange is.
- 256 byte for data sending from Host to Reader (downlink)
- 256 byte (FSDI = 8) for data sending from Reader to Host (uplink).
REQUEST-DATA
6
7
(8...n-2)
[0xBE]
MODE
(DATA)
RESPONSE-DATA
6
(7)
(8...9)
(10...n-2)
STATUS
(PSTAT)
(BLK_CNT)
(DATA)