6.1.6. [0x23] Read Multiple Blocks (extended Address Mode)
This command reads one or more data blocks.
The supported ISO15693 Host commands depend on the different ISO15693Transponder types, which are described in
chapter
Fehler! Verweisquelle konnte nicht gefunden werden.
.
REQUEST-DATA
6
7
8
9
1 or 2 Bytes
( def. by
EXT_ADR)
1 Byte
0x23
MODE
UID
BANK
DB-ADR
DB-N
RESPONSE-DATA (STATUS = 0x95)
7
ISO15693
ERROR
RESPONSE-DATA
7
8
9
10...n
DB-N
DB-SIZE
SEC-STATUS
DB
Repeated DB-N times
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
EXT_ADR
0
SEC
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
SEC:
b0
SEC-STATUS always = 0x00
b1
security status of following data block in SEC-STATUS
EXT_ADR:
If this bit is set the command includes extended address fields.
b0:
Transponder memory addressing is done by the 1 byte DB-ADR Field.
b1:
Transponder memory addressing is done by BANK and
2
byte DB-ADR
Field
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed