OBID
®
classic-pro
Manual
ID CPR30.xx
FEIG ELECTRONIC GmbH
Page 56 of 126
H01114-0e-ID-B.docx
6.1.2. [0x25] Select
This command sets one Transponder to the Select State. Only one ISO Transponder can be se-
lected at once.
The supported ISO Host commands depends on the Transponder types, they are described in chap-
ter 8. Supported ISO Host commands.
REQUEST-DATA
6
7
(8)
(9)
8 (9) (10)...15 (252) (253)
[0x25]
MODE
TR_DRV
UID_LEN
UID
RESPONSE-DATA (only if STATUS = 0x95)
(7)
ISO-ERROR
RESPONSE-DATA (only if the MODE-bit CINF was set in the request and STATUS = 0x00)
(7)
(8)..n
FORMAT
CARD_INFO
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
DRV_SEL
CINF
UID_LF
0
ADR
ADR:
b001
addressed
UID_LF:
If this bit is set the parameter UID_LEN must inserted into the command.
b0:
The protocol UID_LEN doesn't include the UID_LEN byte and
the UID field has a fixed length of 8 byte, from byte 6 to byte 13.
b1:
The protocol includes the parameter UID_LEN. The UID has a variable
length as defined in UID_LEN.
CINF:
b0:
don't return card-information
b1:
return the card-information within the select response.
DRV_SEL:
b0:
No extra byte TR-DRV included in request data
b1: