6.3.3. [0x2B] ISO14443-4 Transponder-Info
This command could be helpful to get further information's about the capabilities of the present
ISO14443-4 Transponder. The included information is transferred from the Transponder. (For fur-
ther Information please see ISO/IEC ISO14443-4)
NOTICE:
This command could be used only after the Transponder was selected (see
REQUEST-DATA
6
[0x2B]
RESPONSE-DATA
7
8
9
10
11
12
FSCI
FWI
DSI
DRI
NAD
CID
FSCI:
Transponder Frame-Size
FSCI
0
1
2
3
4
5
6
7
8
9..255
Bytes
16
24
32
40
48
64
96
128
256
RFU
FWI:
Frame Waiting Time Integer of the Transponder.
Frame Waiting Time (FWT) = 302µsec * 2
FWI
(FWI
max
= 14 4949 ms)
DSI
(Divisor send Integer)
:
Displays the present supported data transfer rate from Reader to Transponder.
DSI
b00
b01
b10
b11
kBit / s
106
212
424
847
DRI
(Divisor receive Integer)
:
Displays the present supported data transfer rate from Transponder to Reader.
DRI
b00
b01
b10
b11
kBit / s
106
212
424
847
NAD:
b1:
NAD (Node Address) supported, if bit is set to 1.
CID:
b1:
CID (Card Identifier) supported, if bit is set to 1.