8.3.11. Texas Instruments (Tag-it HF-I Standard, Tag-it HF-I Pro)
The command codes listed in the following table support the various Transponder commands and operations that are
available for Tag-it HF-I Standard and Tag-it HF-I Pro Transponders.
IC manufacturer identifier: 0x07
Product ID / Config : (xxxx / nnn)
Tag-it HF-I Standard = b1100 000
Tag-it HF-I Pro
= b1100 010
Memory organization: 8 x 4 Byte = 256Bit user data
Number of blocks
11 (user area: 0...7)
Block size
4 byte
Command
Code
Function
Mode
Comment
non-
addressed
addressed
select
0x01
Inventory
-
-
-
0x02
Stay Quiet
-
-
0x22
Lock Block
-
WR-OPTION = 1
**
0x23
Read Multiple Blocks
-
DB-Size = 4
0x24
Write Multiple Blocks
-
DB-Size = 4
WR-OPTION = 1
**
0x25
Select
-
-
-
-
0x26
Reset to Ready
-
-
-
-
0x27
Write AFI
-
-
-
-
0x28
Lock AFI
-
-
-
-
0x29
Write DSFID
-
-
-
-
0x2A
Lock DSFID
-
-
-
-
0x2B
Get System Information
-
-
-
-
0x2C
Get Multiple Block Security
Status
-
-
-
-
Custom specific commands
0xA4
Kill
-
-
only Pro
0xA5
WriteSingeBlockPwd
-
-
only Pro
**
The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter in
“CFG4 Transponder Paramters” is set to “00: automatically set”
(