3.8. CFG16: Persistence Reset
The parameters in CFG16 are used to configure the timing conditions when the Reader performs
self initiated a reset of the RF antenna field.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
PER-RESET-TIME-ANT
0x00
0x00
0x00
Default
0x00
0x00
0x0000
0x00
0x00
0x00
0 x 5ms = 0ms
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
PER-RESET-TIME-ANT:
The timer value specifies a time which determines the reset of the RF filed by the Reader.
The timer PER-RESET-TIME-ANT starts after the Reader gets a response at the antenna.
After this time has expired the Reader resets the RF-Field.
Timer ticks = 5ms
Maximum timer value = 5ms x 65534[0xFFFE] = 5,46125 min.
The value 65535 [0xFFFF] indicates that no RF-Reset is performed by the Reader