OBID
®
classic-pro
Manual
ID CPR30.xx
FEIG ELECTRONIC GmbH
Page 116 of 126
H01114-0e-ID-B.docx
8.3.9. STMicroelectronics (LRI64)
IC manufacturer identifier: 0x02
memory organization: 16 x 1 Byte = 128Bit
Number of blocks 5 (user area: 10...14)
Block size
1 byte
Command
Code
Function
Mode
Comment
non
addressed
addressed
select
0x01
Inventory
-
-
-
0x02
Stay Quiet
-
-
0x22
Lock Multiple Blocks
-
-
-
-
WR-OPTION = 0
*
0x23
Read Multiple Blocks
-
In non addressed mode DB-N
must be 1
0x24
Write Multiple Blocks
-
DB-Size = 1,
WR-OPTION = 0
*
0x25
Select
-
-
-
-
0x26
Reset to Ready
-
-
-
-
0x27
Write AFI
-
-
-
-
WR-OPTION = 0
*
0x28
Lock AFI
-
-
-
-
WR-OPTION = 0
*
0x29
Write DSFID
-
-
-
0x2A
Lock DSFID
-
-
-
0x2B
Get System Information
-
0x2C
Get Multiple Block Security
Status
-
-
-
The WR-OPTION will be set automatically by the FEIG Readers if the RW-OPTION parameter in