3.5. CFG4: Transponder Parameters
The parameters of the CFG4 configuration block contain general Transponder settings.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
0x00
0x00
ISO15693-
MODE
ISO15693-
AFI
ISO15693-
OPTION
Default
0x00
0x00
0x00
0x00
0x10
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
0x00
ISO14443B-
AFI
0x00
0x00
0x00
0x00
ISO15693
BLOCKSIZE
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x04
ISO15693-MODE:
(only ISO15693 Transponders)
Bit:
7
6
5
4
3
2
1
0
Function
0
0
AFI
NO-TS
0
0
0
0
NO-TS
b0:
16 timeslots
b1:
1 timeslot
NOTICE:
Anticollision is only possible if NO-TS=16.
AFI
b0:
disabled
b1:
enabled
ISO15693-AFI:
(only ISO15693 Transponders)
Application Family Identifier to select a Transponder
ISO15693-OPTION:
(only ISO15693 Transponder)
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
WR-OPTION
0
0
WR-OPTION:
b00:
automatically set
b10:
Tag Option = 0
b11:
Tag Option = 1
NOTICE:
If WR-OPTION is automatically set, the Reader sets the WR-OPTION to 0, if the ISO-Host
Command is in non-addressed mode.