Installation
Description, Specifications, Installation, Operation, and Service Manual
5. Connect the black line wire from the 15 A breaker to the DIN rail mounted terminal
block labeled F2-Line in the UVIC cabinet.
6. Optionally, connect a green ground wire from the breaker panel earth ground to the
green ground block in the UVIC cabinet or run a ground lead from the external 3/8
inch ground stud on the UVIC cabinet to earth ground.
7. To avoid shorting the output of the charger, do not apply AC power to the UVIC
controller before making the battery connections described later in this section.
Wiring Guidelines for the 240 Vac Electrical Service
To wire for the 240 Vac electrical service:
1. Install a dedicated 15 A 2-pole circuit breaker in an existing breaker panel or install a
new breaker panel if necessary for the UVIC.
2. Install conduit from the beaker panel to a conduit entrance in the bottom of the
UVIC. Ensure the conduit is adequately grounded.
3. Route user-supplied 12-14 AWG wires (2 black, 1 green - optional) through the
conduit from the UVIC cabinet and the fused breaker panel (or as otherwise specified
by code).
4. Connect one line wire from the 15 A breaker panel to the fused DIN rail mounted
terminal block labeled F1--L1 in the UVIC cabinet.
5. Connect the other line wire from the 15 A breaker to the DIN rail mounted terminal
block labeled F2--L2 in the UVIC cabinet.
6. Optionally, connect a green ground wire from the breaker panel earth ground to
the green ground block in the UVIC cabinet or run a ground lead from the external
3/8 inch ground stud on the UVIC cabinet to earth ground.
7. To avoid shorting the output of the charger, do not apply AC power to the UVIC
controller before making the battery connections described later in this section.
Battery Connections
When installing or removing batteries, take care to avoid shorting battery
terminals to metal surfaces. Failure to do so could result in serious personal
injury or death. Batteries miswired can cause serious personal injury or
death. Read and understand the following information before making actual
connections.
To connect the battery:
1. The battery disconnect plug is located behind the cover plate on the right side of the
amplifiers. Disconnect the battery cable from the motherboard by grasping the black
connector with the large 8 AWG red and black wires and unplugging it from the
motherboard.