Operations
UltraVoice Indoor Controller (UVIC)
When the ACTIVATE button is released, the microphone is disconnected and the
function stops until the ACTIVATE button is pressed again.
Figure 16 Using UVLOC Controls
Activating a Digital Voice Message
To activate a digital voice message:
1. Press the ARM switch for 1 second.
2. Turn the dial to one of the messages.
3. Press the ACTIVATE button.
Recording a Digital Voice Message
To record a digital voice message:
1. Press the ARM switch for 1 second.
2. Turn the dial to RECORD.
3. Hold down the ACTIVATE button while speaking within 12 inches of the
microphone and release button to stop recording.
RECORD re-records the previous message each time the ACTIVATE button is
pressed. Up to 2 minutes of recording time is available for the record function. The
PLAYREC function play-backs the digitally recorded message.
The CANCEL/DISARM button stops any function in progress and disarms the control
panel(s) which also turns off the ARM LED on the control panel(s).
A function description area is reserved on the bottom of the UVLOC panel to place a
label describing each of the functions available with a meaningful description.