56
Operations
UltraVoice Indoor Controller (UVIC)
Table 41 Remote Activation Connections (JP14)
JP14 Terminal Function
1—COM
Common
2—F1
F1—Activates functions 1
3—F2
F2
—
Activates functions 2
4—F3
F3
—
Activates functions 3
5—F4
F4
—
Activates functions 4
6—F5
F5
—
Activates functions 5
7—F6
F6
—
Activates functions 6
8—F7
F7
—
Activates functions 7
9—F8
F8
—
Activates functions 8
10—COM
Common (Reset)
Sensor Inputs (JP15)
Terminal block JP15 is located at the bottom of the backplane motherboard. Use sensor
inputs to detect and notify conditions occurring at an RTU location.
Table 42 Sensor Connections (JP15)
JP15 Terminal
Function
1—COM
Common
2—SPR #1
Spare #1
3—COM
Common
4—INTR
Intrusion
5—COM
Common
6—SOL
Solar
7—COM
Common
8—AC
AC Power
9—COM
Common
10—600 PTT
600 PTT
11—COM
Common
12—SPR #2
Spare #2
Spare 1 and 2 (JP15: pins 1 and 2)
Use for user-defined application.
Intrusion (JP15: pins 3 and 4)
Alerts the controller when one of the unit’s doors has been opened. Low is intrusion pass.
Solar
(JP15: pins 5 and 6)
Use to sense operation of solar power system.
Jumper JP15: pins 5 and 6 when using solar. This jumper enables solar mode, which
causes the system not to report a failure during low-light conditions or at nighttime. This
is done by locking in a power pass until a master reset. For solar panel testing during the
day, initiate a master reset, wait 15 seconds, and then poll.
Содержание UltraVoice UVIC
Страница 61: ...61 Operations Description Specifications Installation Operation and Service Manual Figure 17 UVLOC Drawing...
Страница 67: ...67 Appendix B Drawings Figure 18 UVIC Wiring Diagram...
Страница 68: ...68 Figure 19 UVIC IP Wiring Diagram...
Страница 69: ...69 Figure 20 UVIC LL Wiring Diagram...