45
Configuring Informers Using Commander Software (Optional)
Setup, Program, and User Manual
Federal Signal www.fedsig.com
The following table describes additional selections in the Digital Voice Upload
programming.
Fields
Description
Duration of
Messages
The total duration of all messages displays at the bottom of the screen.
Series C Informers can store over four hours of audio. Series A and B
Informers have 15-minute storage capacity. If more than 15 minutes of
messages are loaded, Out of Limit displays as a warning because the
capacity of the RTU has been exceeded or is approaching.
NOTE
: Depending on the content and number of messages, it may be
possible to upload more than 15 minutes into the RTU. If more than 8
minutes is uploaded, confirm the last message has been successfully
uploaded into the RTU by playing the last message. The absolute
maximum duration is 15 minutes 45 seconds.
Message
Number
Messages are assigned a Message Number based on the number of
messages currently programmed in the RTU. If there are currently 3
messages in the RTU, the first new message is assigned number 4. The
assigned message number appears in the text box on the right after each
message is uploaded.
All Series C Informers can store over 4000 WAV files. Series A and B
Informer100 can store a maximum of 250 WAV files. Legacy Informer-IP
Wall Mount and Desk Mount models have a limit of 100 messages with
firmware v1.18.0.2 or less.