SOFTWARE
ADMINISTRATOR SETTINGS
: modify the administrator password
OUTPUT SETTING
: the output se ng includes a hidden An -Clip limiter:
Max input level is +20dBu and Max output level is +18dBu, this means that
when input is going over +18dBu, if no Limit process on output, the output
will be clipped up to +2dB in excess.
The An -Clip Limiter is limi ng up to +2dBu the output when input is
exceeding
The same applies to dual-channel, that is, two channels can be applied with
plug-ins and the corresponding FIR with a sampling rate of 96kHz needs to
be used, and the FIR generated by a third party can be imported here (Note:
the FIR filter of the input and output channels runs at 48kHz sampling rate,
the audio stream is processed by FIR through down-sampling and then up-
sampled back to the DSP processing chain. Similarly, the FIR convolu on
generated by AEQ is also running at a sampling rate of 48kHz , so here 96k
FIR can only be imported from the file).
When selec ng RTA and advanced signal generator.
The signal generator and RTA icons will appear.
This is the main interface when the advanced generator and RTA are not
selected
30