Basic Training Workbook
Version 1.5 - August 2007
53
Chapter 4: Basic Part Measurements (Metrology Mode)
Verifying the Alignment
To verify that the alignment orientation was properly set, select 3D CALIPER, select the
SETUP tab, select the USE ALIGNMENT check box, then select the 3D tab. Observe the
X,Y,Z readings as you move the probe around the part.
Select CLOSE to exit 3D Caliper.
Inspecting the Part
Let's now check the part using the part print on page 46 and the pre-established alignment.
3
Type a name for your measured hole ("
Hole1
" is recommended), or use the default name.
4
Choose the previously measured face for the hole. The digitized points are projected to the
face before the best-fit calculation.
5
Select OK to measure Hole #1.
1
Select the Hole command.
2
Select the RUN button.