Basic Training Workbook
Version 1.5 - August 2007
59
Chapter 4: Basic Part Measurements (Metrology Mode)
6
Choose Hole #1.
N
OTE
:
Features without nominal values are not available.
7
Select the TOLERANCES tab.
•
On the drawing, the "M" next to the tolerance value in the feature indicates MMC
tolerance (Maximum Material Condition).
8
Uncheck RFS (Regardless of Feature Size).
9
Select the MMC tolerance field and type Position Tolerance =
1.0
.
10 Select OK to review the results.
11 Select OK to add the dimension to your FARO Gage part file.
Review Results and Reports
To review the results of your measurements at any time, select a feature or dimension from the
list and choose REVIEW.
You can also edit the nominal information or remove features from the list.
The FARO Gage Reports drawer contains all the commands to create reports for your part.
The Reports drawer is only available in METROLOGY mode.