90
Machine-specific alarms
ID
Alarm text
Possible cause
Possible remedy
602
Connection lost.
The connection to the ERC module
has been lost.
Check the cables.
603
Connection disrupted.
The connection to the ERC module is
interrupted.
Check the cables.
604
Supply voltage too low.
The supply voltage of the ERC
modules is too low.
Check the supply voltage and check
the vehicle battery.
605
Short circuit.
There is a short circuit in the ERC
modules.
Check the cables.
606
Open load current circuit.
An open load circuit has been
detected for the ERC modules.
Check the cables and make sure the
disconnect connector is available.
607
Recognizes. ERC module error.
The configuration is incorrect.
Check the IN and OUT configuration.
608
Seed flow was not recognized.
The seed flow system did not detect
any seed flow.
Check the seed flow system.
609
Seed flow was detected.
Seed flow occurred in the tramline.
Check the tramline switching. Kalpak
tightness check.
611
Low tank level.
There is little seed of fertilizer in the
hopper.
Fill the hopper.
612
The tank is empty.
There is no seed or fertilizer in the
hopper.
Fill the hopper.
613
Exceeding the time when closing
the section.
It takes too long to close the left
section.
Make sure something is blocked.
617
Defective charger.
The charger alternator is defective.
Check the charger alternator.
618
No product flow was detected in the
active row.
No product flow was detected in the
active row.
Check the product flow, or some
supply lines are blocked.
619
Too high flow detected in the active
row.
Product flow detected too high was
detected in the active row.
Check the calibration.
620
Product flow too low in the active
row detected.
Too little product flow was detected in
the active row.
Check the calibration.