92
ID
Alarm text
Possible cause
Possible remedy
667
Sensor error detected
PLANTirium®. LIN-BUS
communication error.
AQ LIN-Bus communication error has
occurred. The sensor did not receive
any messages from the LIN-Bus.
Check the cables.
668
Working speed is out of speed
range.
Working speed is too high or too low.
Make sure you are within the speed
range you found during the
calibration test.
669
An error has been detected in the
PLANTirium® sensor. Connection
lost.
The connection to the
PLANTirium®
sensor has been disconnected.
Check the cables on the sensor.
670
Seed flow system error. Error:
Sensor:
An error has occurred in the seed flow
system.
Check the seed flow system.
671
Seed flow system error.
An error occurred in the seed flow
system.
Check the seed flow system.
672
Product flow detected in inactive
row.
Product flow detected in inactive row. Check disconnection.
680
Connection lost.
The connection to the
monitoring/control module has been
disconnected.
Check cables.
681
Undefined module index.
An unconfigured monitoring/control
module was found.
Check the number of configured or
connected modules.
685
An error been detected in the
control module.
Voltage drop, module error.
It is necessary to perform diagnostics
and possible replacement of the
module.
686
Supply voltage too low.
The supply voltage at the
monitoring/control module is too low.
Check the cables.
688
The target value cannot be met.
Seed coulter pressure.
The required setpoint for the linear
actuator has not been reached.
Check the linear actuator for
blockage.
689
The target value cannot be met.
Working depth.
The required setpoint for the linear
actuator has not been reached.
Check the linear actuator for
blockage.
690
An error has been detected in the
CAN repeater. 5V
– Wrong voltage.
The CAN repeater is defective.
Contact customer service.
691
An error has been detected in the
CAN repeater. 3.3 V
– Wrong
voltage.
The CAN-Defeater is defective.
Contact the customer service.
692
An error has been detected in the
CAN repeater. 2.5 V
– Wrong
voltage.
The CAN-Defeater is defective.
Contact customer service.
693
Error detected in CAN-Repeater 12
VE- Faulty voltage.
The power supply to the electronics is
defective.
Check the cables.
Содержание FALCON 3