91
ID
Alarm text
Possible cause
Possible remedy
621
Not available for this product no
dataset.
A calibration test has not yet been
performed for the product in question.
Perform a calibration test before
working with the product.
622
The sowing test button is activated.
The sowing test button was activated
before opening the calibration screen.
Release the sowing test button.
630
Connection lost.
The connection to the MRC module
has been lost.
Check the cables.
631
Undefined module index.
A software error has occurred.
Contact customer service.
636
There is no seed for overdosing.
Too little seed was detected during
pre-dosing.
Make sure that sufficient seed is
available.
638
The engine stopped.
The MRC engine stopped.
Check the cables.
639
Current too high.
The MRC motor requires too much
current.
Make sure something is blocked.
640
No speed was reached.
The MRC module did not reach the
required speed.
Check the cables. Check the seed
drills.
641
Power voltage too low.
The power voltage of the MRC
module is too low.
Check the cables.
642
Electronics voltage too low.
The electronics voltage at the MRC
module is too low.
Check the cables.
643
Sensor voltage too low.
The sensor voltage at the MRC
module is too low.
Check the cables.
650
Connection lost.
The connection to the
AIRidium®
sensor has been disconnected.
Check the cables.
651
Undefined module index.
An error occurred of the
AIRidium®
module.
Contact customer service.
660
Connection lost.
The connection to the CAN Repeater
has been disconnected.
Check the cables.
663
Drop below minimum voltage.
The voltage is lower than the pre-set
minimum supply voltage.
Check wiring and supply voltage.
664
Sensor error detected
PLANTirium®. Pollution rate too
high.
The sensor is dirty. Sensitivity does
not match the selected product.
Clean the sensor and/or change
the sensitivity in the product.
665
An error has been detected in the
PLANTirium® sensor. Faulty
sensor transmitter.
The sensor transmitter is defective.
Check the cables on the sensor.
666
An error has been detected in the
PLANTirium® sensor. Not
achieved.
The minimum supply voltage has not
been reached.
Check the cables.
Содержание FALCON 3