61
11.
Required value
– sowing dose
Example:
One dispenser: Total dispenser requirement 200 kg/ha, set 200 kg/ha.
Split-up EC: Requirement 200 kg/ha, set to each dispenser 100 kg/ha.
Split-up HM: Requirement 200 kg/ha, set to each dispenser 200 kg/ha.
12.
Calibration factor - from the table of calibration factors
– page
64
.
Example:
150 g/rev.
-
Calibration factor
– number of grams per revolution of the roller.
-
The calibration factor from the table is for guidance only. After the sowing test, the calibration factor
is automatically recalculated.
13. Hang the calibration bucket.
14. Open the slider.
15.
-Fill the roller.
16. Pay attention to the selected units on the scaling device.
17. Empty the bucket, then hang it on the scale and use the TARE function.
18. Hang the calibration bucket on the dispenser.
19.
-Activate calibration button.
20. Hold down the calibration button. There must be a large amount of seed in the bucket for accurate
calibration.
Example: Wheat 4 kg, Rape 0,5 kg
21. After releasing the calibration button, weight the amount of seed in the calibration bucket.
22. Enter the weight into the terminal. For this entry use a window with the name
Acquired value
.
23. Check that you are comfortable with minimum and maximum
speed
.
-
If it does
NOT COMPLY,
replace the roller and repeat the test.
-
Minimum speed is too high= select a smaller roller (
ideal speed is from 1,5km/h
).
-
Maximum speed is too low= select a larger roller.
-
Deviation
– For a roller dispenser should not be greater than 1 %, for auger metering unit 5 %.
-
If the deviation is too large, confirm the calibration
and repeat it again from
point 17.
24. If the range and deviation match, confirm
the calibration
25. Repeat the same calibration procedure for the other dispenser.
Working speed range of electric
motors is 15-100% (you will find this value on the work screen).