88
Regulations alarms
ID
Alarm text
Possible cause
Possible remedy
400
The configured required blower
speed is invalid. Product: xxxx.
The set required speed is outside the
specified fan drive limits for the
respective product.
Change the minimum and maximum
limits of the required product speed.
401
The blower rotates too slowly.
The current fan speed is lower than
the minimum allowed.
Increase fan speed.
ID
Alarm text
Possible cause
Possible remedy
402
The blower rotates too fast.
The current fan speed is higher than the
value entered in the parameter
„Blower
speed tolerance“.
Reduce the fan speed or change the
tolerance limit.
403
Pressure too high.
The pressure of the linear encoder is
higher than the value of the
“Maximum
value” parameter.
Reduce the pressure or change the
parameter “Maximum value”.
404
Pressure too low.
The pressure of the linear encoder is
lower than the value of the “Minimum
value” parameter.
Increase pressure or change
parameter
“Minimum value”.
405
Dosing has been stopped since the
working position has not been
reached. Excavate the sowing
section.
The machine is not in the working
position.
Excavate the sowing section.
406
Dosing was stopped because the
machine was not completely raised.
Excavate the sowing section.
The machine was not fully raised.
Excavate the sowing section.
407
The dispenser drive is stopped.
The current speed of the dosing drive is
lower than the minimum speed.
Stop now! Eliminate the cause.
408
The metering shaft is stationary.
Speed sensor on the dosing shaft does
not register any movement of the dosing
shaft.
Stop now! Eliminate the cause.
410
The dispenser drive is outside the
control area.
The current dosing drive speed is higher
or lower than set speed.
Drive slower/faster or use a
larger/smaller metering unit.
411
The dosing drive cannot comply
with the setpoint.
You are driving too fast or too slow. It is
not possible to reach the required value
at the current speed.
Drive slower or faster so she can
control unit to regulate the sowing
rate.
412
The application has stopped due to
a fatal error.
An error has occurred. This error always
occurs in combination with another
error.
Please fix the related error.
413
The application was stopped due to
high driving speed.
Driving speed is too high.
Reduce the speed.
Содержание FALCON 3