f1
HOW TO USE YOUR RIVETING TOOL
(fig.
f1-f2-f3-f4
)
To install the rivet, hold the riveting button
D
(
f1
) down for
at least 0.5 seconds. In the event of a continuous use of the
tool, be sure to let it cool down completely every two battery
replacements.
WARNING!
Keep truncated stems in a specific container.
Dispose of stems properly.
DISPLAY
This riveting tool has a display
F
(
f2
) ) with the following
functions:
G
- battery charger (
b
).
H
- cycle counter (
c
).
I
- totalizer (
t
).
The display
F
turns on by pressing the riveting button
D
(
f1
).
Press ( ) to shift from one function to another.
BATTERY LEVEL
This riveting tool has a display, which indicates the battery
charge level.
L
- Maximum battery level (
Hi
).
M
- Minimum battery level (
Lo
).
The display turns on by pressing the riveting button
D
(
f1
).
Replace and charge the battery when it reaches its minimum
level
M
(
f2
).
Warning:
to increase the battery life, prevent it from flattening
completely.
CYCLE COUNTER
This machine is equipped with a cycle counter and a totalizer,
which are viewed through the display
F
(
f2
).
Press ( ) to shift from one function to another.
f2
The cycle counter is useful for the following:
- knowing the average durability of the clamps and programming
their cleaning
- verifying how many rivets are installed during the work cycle
- etc
The cycle counter can display 6 numbers MAX, displayable in
three groups of two figures.
Example: Read 45 cycles
Press ( ) holding it down for 3 seconds to reset the cycle
counter.
The totalizer measures the entire lifespan of the riveting tool
and cannot be reset.
GB
18
EB 400
Date 05-2017
Revision - 02
D
STEP 1
STEP 2
STEP 3
G
H
I
L
M
F