To move between menu items are UP and DOWN buttons. To
enter the selected menu item, press the OK button. Exit to menu
provides a superior level of the RESET button.
Menu -> Mode
Mode menu lets you select the basic mode of operation, ie
whether the meter will measure the duration of the high state at
the entrance gate or measured is the time between two
consecutive pulses. Scheme of Menu ->.
Measurement of time between two pulses
In this mode, the counter measures the time between two
successive pulses given at the entrance gate. The advent of
pulsed positive (transition from low to high) starts counting time.
Re-emergence of such an impulse to stop counting and the
freezing of the meter. Another positive trigger starts counting
continued. When the meter reaches the preset by the user of a
change in the state of relay outputs (NO, contact closure), and
stop counting the time. At the same time the display shows STOP
and highlighting the display flashes three times.
Start a new cycle is possible only after the timer expires, the level
of the control panel (by pressing the RESET button), or via an
external reset input. To protect the system against accidental
erasure of the counter, a zero signal is activated only after three
seconds after you press the RESET button or from the input
signal is given zero.
Set value
M
E
T
E
R
P
U
L
S
E
S
R
E
S
E
T
J
O
IN
T
ON
START
STOP
START
STOP
SET VALUE
M
E
T
E
R
P
U
L
S
E
S
R
E
S
E
T
J
O
IN
T
ON
START
STOP
START
STOP
ATTENTION!
Meter retains its current state after turning off the power supply
voltage. This means that after re-power the system restore all the
settings are both meter and meter indication and relay output
status.
Programming of meter
Meter configuration is performed using a control panel with a
keyboard and display. Entry to the programming mode the meter
is done by pressing the MENU button.
This doesn’t include the loop mode, where the reset is only
possible through an external signal to a zero, and the pulse
duration can not be less than ten seconds
Course of conduct in the definition mode is as follows:
1) By the button MENU pass to main menu of meter.
2) By buttons UP or DOWN select item Menu -> Mode and press
OK.
3) Then shows Menu -> Mode included two position Mode ->
Lvele and Mode - > Slope. Level means that the meter will
measure the duration of the high state at the entrance
bramkującym.
Slope will be counted the time between successive pulses on the
input given gate. UP and DOWN buttons to select the appropriate
option and click OK. Approval of the selected option is indicated
by displaying the message saved with the name of the selected
parameter
4) From edition mode can move out by button RESET. It cause
return to main menu, without save all put changes..