Set ZERO 

This menu is use to reset value of total meter.

Pressing the OK button will reset reports of total meter to without 
any additional enter.

00000000

TOTAL:

Set ZERO

 

MENU

OK

LANGUAGE

This  menu  make  possiblity  to  choose  language  in  wich  will 
display  information  .You  can  choose  polish,  english,  russian 
language. 

OK

RESET

p

q

 

MENU

 LNAGUAGE

 LNAGUAGE

 LNAGUAGE

 LNAGUAGE

 

Polish

 

English

 

English

 

Polish

Saved

Saved

OK

To change the language, select the menu language and press 
OK.  Then,  using  the  UP  and  DOWN  buttons  to  select  the   
language. Enter by OK. Confirmation of changes is displayed in a 
new language set, which is shown in the above picture. To exit the 
menu without saving changes is possible by   press the RESET 
button.

Filtr
NO

Filtr

   2Hz

Filtr

  

 

5Hz

SAVED

xxxxHz

Filtr

 500Hz

Filtr

1000Hz

RESET

p

q

FiltrDC

 

MENU

OK

OK

After you select a menu FiltrDC press OK. Then, using the UP 
and DOWN buttons to select the appropriate frequency filtering 
and approve it OK. Exit menu without saving changes is possible 
by  pressing  the  RESET  button.  Set  the  menu  item  in  FiltrDC 
doesn’t mean exclusion of the internal filter. FiltrDC doesn’t work 
if you set the meter to the signal AC_50 Hz.

WIRING DIAGRAM

supply

24÷264V AC/DC

INPUT: voltage - low status

0÷5VAC/DC

            voltage - high status

10÷264VAC/DC

            frequency for signal DC

<5kHz

            frequency for signal AC

<50Hz

RESET: voltage

24÷264V AC/DC

current load of joint 1P

8A

power consumption

1,5W

working temperature

-20÷50°C

connection

screw terminals 2,5mm²˛

dimensions

3 modules (52,5mm)

fixing

on rail TH-35

TECHNICAL DATA

8

4

3

RESET

INPUT

-/~

-/~

AC/DC

1

2

11

12

7

10

+/~

+/~

1.  Take  OFF  the  power  switchgearbox  in  which  the  device  is 
attached. 2. Put the device to the rail. 
3. Connect the power cables to joints 1 and 2. 
4.Connect other cables with wiring diagram. Please note that in 
the cause of work with DC signals, it is important to preserve the 
appropriate polarity.

ASSEMBLY

A090729

Содержание CLG-03

Страница 1: ...o reset the current cycle of meter The programming mode allows you to go back to the higher level menus If the RESET button is pressed while editing a parameter the program comes from the editing mode without saving changes OK FUNCTIONING Measurement of the duration of the high In this mode the user specifies a set value of time the meter counts all the time in which the input is given gates high ...

Страница 2: ...on or from the input signal is given zero Set value METER PULSES RESET JOINT ON START STOP START STOP SET VALUE METER PULSES RESET JOINT ON START STOP START STOP ATTENTION Meter retains its current state after turning off the power supply voltage This means that after re power the system restore all the settings are both meter and meter indication and relay output status Programming of meter Meter...

Страница 3: ...aved with the name of the selected parameter Proceedings in determining the time display format is as follows 1 By button MENU pass to main menu 2 By buttons UP and DOWN select item Menu Format and press OK 3 Then shows Menu Format included follow items Format 6min Format 10min By buttons UP and DOWN select correct option and press button OK Enter choosen option is indicated by disply message Save...

Страница 4: ...e 4 To exit the option to choose the language without any changes press the RESET button Menu Light This parameter allowsto specify a way of highlight a meter display You can set the highlight permanently highlight or highlighting only for 60 seconds after you press any button To determine how the highlight you need 1 Pass to menu by pressing a button MENU 2 By buttons UPor DOWN select Menu Light ...

Страница 5: ...authorised modifications are to be made in the relay otherwise the device may be damaged or malfunction which in turn may lead to damage of the protected engine and jeopardise its operators Should this warning be ignored the producer cannot be held responsible for any related events and is entitled to deem this warranty invalid in the case of any complaint External signal does not permanently remo...

Страница 6: ...tended for counting the number of working hours in automatic production processes or the number of device working hours which due to safety requirements and operation efficiency have limited overhaul life i e operational capacity that may notbeexceeded e g advancedpowerunits specialradioactivelamps etc ASSEMBLY FUNCTIONING CLG 13T meter is an electronic one way meter enabling the counting of worki...

Страница 7: ...non voltage type internal battery baterry life 5 years read input voltage 4 30V DC input RESET 4 30V DC display 6 characters h 6 7mm precision 1 1digit working temperature 10 40 C dimensions 48 24 52mm fixing hole 45 23mm TECHNICAL DATA U URESET Do not dispose of this device to a garbage bin with other unsorted waste In accordance with the Waste Electrical and Electronic Equipment Act any househol...

Страница 8: ... are intended for counting the number of working hours in automatic production processes or the number of device working hours which due to safety requirements and operation efficiency have limited overhaul life i e operational capacity that may not be exceeded e g advanced powerunits specialradioactivelamps etc CLG 14T meter is an electronic one way meter enabling the counting ofworkinghoursin0to...

Страница 9: ...terylife 5years counteriputvoltage 24VAC DC maximumcountigfrequency 200Hz RESETinput non voltagetype display 8characters h 6 7mm precision 1min working temperature 10 40 C dimensions 48 24 52mm 45 23mm fixing hole D141114 AC DC RESET 5 9 0 8 3 1 2 5 9 8 0 8 4 F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice phone fax 48 42 215 23 83 227 09 71 POLAND http www fif com pl e mail fif fif com...

Страница 10: ...0V AC DC 1 Disconnectthepowersupply 2 Slidethemountingbracketofffromthebodyofthecounter 3 Put the counter into the mounting hole insert the fastening metalplateandtightenthenut 4 Connect the L N voltage which is an indication of the controlled device operation to the terminals of the counting input D160309 L N Purpose Functioning WARRANTY The F F products are covered by a warranty of the 24 months...

Страница 11: ...the casing front panel control It consists of a two lines eight alphanumeric display and placed under it keyboard with five buttons 01304569 TOTAL Two lineseight alphanumeric display Control buttons CLI 01 RESET OK MENU p q Display present information about the current state of work and in programming mode allows the configuration of the meter parameters The buttons on the control panel perform th...

Страница 12: ...e of type signal for the RESET input 3 FiltrDC FiltrDC menu is used to define the parameters of the internal digital filter It can help reduce frequency counting pulses to the set value and thus reduce the possibility of wrong work of system caused by interference such as by contact vibration systems Diagram of the digital filter configuration is presented in the following picture 00000999 MENU TH...

Страница 13: ...s is possible by press the RESET button Filtr NO Filtr 2Hz Filtr 5Hz SAVED xxxxHz Filtr 500Hz Filtr 1000Hz RESET p q FiltrDC MENU OK OK After you select a menu FiltrDC press OK Then using the UP and DOWN buttons to select the appropriate frequency filtering and approve it OK Exit menu without saving changes is possible by pressing the RESET button Set the menu item in FiltrDC doesn t mean exclusio...

Страница 14: ...for counting AC DC voltage signals generated by additional peripheral devices in order to determine the number of carriedoutworkingcyclesinautomaticssystems e g inordertocontrol the number of press strokes the number of revolutions of a rotating device thenumberofcomponentsleavingtheproductionline etc Assembly Functioning CLI 11T meter is an electronic one way meter enabling the counting of pulses...

Страница 15: ...ry battery life 5 years read input voltage 110 240V AC DC max coting frequency 200Hz input RESET non voltage type display 8 characters h 6 7mm precision 1 1digit working temperature 10 40 C dimensions 48 24 52mm fixing hole 45 23mm TECHNICAL DATA U URESET 5 9 0 8 3 1 2 5 9 1 8 4 9 F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice phone fax 48 42 215 23 83 227 09 71 POLAND http www fif com...

Отзывы: