3) You will see the Menu -> Light containing the following items:
Light -> At constant - The display will be constantly illuminated.
Signaling reaches the setpoint will meter that the display will flash
three times, then returns to the highlight state. Light -> button -
The display will be highlighted only when you press any button
and 60 seconds after him. In case of the meter setpoint
highlighting blinks three times then turns off. UP and DOWN
buttons to select the correct option and click OK. Remember the
new parameter value is indicated by displaying the message,
Saved with the new value of the parameter, then the program
returns to the Menu -> Light.
4) To exit the parameter editing without saving changes, press the
RESET button.
To define the type of input signal is needed:
1) Pass to menu by pressing a buttin MENU.
2) By buttons UP or DOWN select Menu -> Signal and press
OK.
3)The will show Menu -> Signal included follow items:
Signal -> Stable_DC
To input of meter will be give
permanent voltage. System will react in this case to set signal
slope, or achieve a high state.
Signal -> AC_50Hz
To input of metrer will be give analog
voltage with frequency 50 Hz. In this case the system will react
to the fact that the emergence of an alternating voltage at the
terminals of control.
By buttons UP or DOWN select correct option and press button
OK. Remember the new parameter value is indicated by
displaying the message. Saved with new parameter value,
after that program back to Menu -> Signal.
4) To exit the parameter editing without saving changes, press
the RESET button.
Menu -> Language
This parameter allows to specify what language you'll see the
messages. To select messages are in Polish, English and
Russian. Menu chart is shown in the figure below.
OK
RESET
RESET
MENU
Saved
Saved
OK
OK
p
q
Button
Button
To change a language of message you need:
1) By button MENU pass to main menu.
2) By buttons UP or DOWN select item Menu > Language and
enter by OK.
3) From list by buttons UP or DOWN select correct item and
enter by OK. Confirmation of the change of language will
appear in the new selected language.
4) To exit the option to choose the language without any
changes, press the RESET button.
Menu->Light
This parameter allowsto specify a way of highlight a meter
display.You can set the highlight permanently highlight , or
highlighting only for 60 seconds after you press any button.
To determine how the highlight you need:
1) Pass to menu by pressing a button MENU.
2) By buttons UP or DOWN select Menu -> Light and press OK.
System -> Password
Password parameter can be used to restrict access by
unauthorized users to meter menu. The password is the number
of accepting values from 0 to 999, but set the password to 0
removes the security of meter. Setting the password other than
zero introduces a meter in the secure mode. To set a password
you need:
1. By button MENU pass to main menu.
2. By buttons UP or DOWN pass to Menu > System and enter by
OK.
3. By buttons UP or DOWN select command System >
Passwordand press a button OK.
4. Meter is now in the mode of implementation of the new PIN,
which is signaled by a message New PIN. Password is entered in
the form of overt and baseline is the previous value of the
password.
5. By buttons UP or DOWN set the appropriate value of sequential
numbers, and use the MENU button, you can go to the next
edition of the numbers. After entering all the required numbers to
confirm a new PIN by pressing the OK button.
6.To exit the editing mode without saving your password, press
the RESET button.
After setting the password to access the menu meter is protected
against unauthorized access. This state is signaled by a key
symbol on the display positioned in the right top of the display.
00000999
>>
Lock MENU
From this moment to enter the configuration menu of meter when
you press MENU first enter the correct PIN.
The PIN is introduced here as classified. That means you edit the
figure is visible, while the remaining two digits are hidden under
asterisk. If you enter an incorrect PIN number is displayed bad
PIN, then the meter will return to display the current value of the
meter.
PIN
>> 0
PIN
>> **6
OK
+1
-1
p
q
MENU
"
00000999
>>
MENU
Mode
MENU
OK
RESET
p
q
MENU
Polski
English
English
Polski
Zapisane
Saved
OK
Language
Language
Language
Language
Permanently
Light
Light
Light
Permanently
System
New PIN
>> 000
New PIN
>> 356
Saved
>> 356
OK
OK
RESET
RESET
+1
-1
p
q
MENU
"
Password