4) By buttons UP or DOWN set correct value digit of edited
position.To pass to edit digit on the next position press button
MENU.
5)In this way, you need to set all digits of set value and enter the
new value.
6) Saving changes is indicated by a message SAVED, after that
program back to Menu -> Threshold.
7) To exit the menu without saving the changes, at any time by
editing press the RESET button.
ATTENTION!
Setting a new threshold resets the current timer. There is no
impact on the timer in the program loop.
Menu -> Format
Format menu allows you to specify the time format displayed by
the meter.The unit is meter hours. The lowest value indicated on
the display is 0.1.Cyfra decimal, depending on the format, might
indicate tenths of hours (6min Format: 0.1 = 6min., For example,
12.4 = 12godz.24min.) Or counted the number of consecutive
10min. hours (10 minutes Format: 0.1 = 10min., for example, 12.4
= 12godz.40min., the counting takes place in the 0.1 ÷ 0.6 on the
value of 0.6 is about 1 meter jump unit (hour).
OK
RESET
RESET
MENU
Format
Format
6 min.
Format
10 min.
Saved
6 min.
Saved
10 min.
OK
OK
p
q
Course of conduct when determining the rounding off is as
follows:
1) By button MENU pass to main menu.
2) By buttons UP or DOWN select item Menu -> Program and
press button OK.
3) Then shows Menu -> Program included follow items:
Program -> Loop mode in which the counting time from zero
up without regard to the setpoint. Meter measures the time until
the meter overflows.
Program -> To UP meter will be time to count up from zero to a
specified (parameter Menu -> Threshold).
Program -> To DOWN zliczanie realizowane będzie w dół,
zaczynając od ustalonej wartości progowej (parameter Menu -
> Threshold), and ending with zero. By buttons UP and DOWN
select correct option and press button OK.. Enter of the
selected option is indicated by displaying the message: Saved
with the name of the selected parameter.
Proceedings in determining the time display format is as follows:
1) By button MENU pass to main menu.
2) By buttons UP and DOWN select item Menu -> Format and
press OK.
3) Then shows Menu -> Format included follow items:
Format -> 6min.
Format -> 10min.
By buttons UP and DOWN select correct option and press
button OK. Enter choosen option is indicated by disply
message. Saved by the name of the selected parameter.
4) To exit the menu without saving the changes, at any time by
editing press the RESET button
Menu -> Signal
Menu specifies the type of signal is connected to the input signal
and gate reset. There are two options here, the signal stable (DC)
and alternating signal (AC).
Menu -> Threshold
The threshold parameter determines the threshold which will be
counted at the time of the selected program to the top, or from
which starts the timer at the bottom on the chosen program. The
threshold parameter has no effect on the work counter, where the
program was chosen loop. Threshold can be set to the nearest
full hour
Proceedings in determining the threshold value is as follows:
1) By button MENU pass to main menu.
2) By buttons UP or DOWN select item Menu -> Threshold and
press button OK..
3) The bottom line will show the current setpoint. Edited currently
digit is signaled by the pulsating cursor.
Menu -> Program
The menu allows you to specify whether the meter will be tracked
from time zero to a preset threshold, counting from the threshold
to zero, or tracked without any restrictions from zero upward until
it reaches the counter overflow.
4) From edit mode you can move out by pressing the RESET
button. This withdrawal of the parent menu without saving
changes.
p
q
OK
Program
MENU
OK
Saved
Program
OK
Program
Saved
OK
Saved
Program
RESET
Loop
Loop
To Up
To Up
To Down
To Down
RESET
000012
Saved
MENU
p
q
+1
-1
"
MENU
OK
000000
OK
RESET
000012
Threshold
Threshold
Threshold
OK
RESET
RESET
Saved
MENU
AC_50Hz
Saved
AC_50Hz
OK
OK
p
q
MENU
MENU
Stable_DC
Stable_DC
SIGNAL
SIGNAL
SIGNAL