4)  By  buttons  UP  or  DOWN  set  correct  value  digit  of  edited 
position.To pass to edit   digit on the next position press button   
MENU.
5)In this way, you need to set all digits of set value and enter the 
new value.
6) Saving changes is indicated by a message SAVED, after that 
program back to Menu -> Threshold.
7) To exit the menu without saving the changes, at any time by 
editing press the RESET button.

ATTENTION!

Setting  a  new  threshold  resets  the  current  timer.  There  is  no 
impact on the timer in the program loop.

Menu -> Format

Format menu allows you to specify the time format displayed by 
the meter.The unit is meter hours. The lowest value indicated on 
the display is 0.1.Cyfra decimal, depending on the format, might 
indicate tenths of hours (6min Format: 0.1 = 6min., For example, 
12.4  =  12godz.24min.)  Or  counted  the  number  of  consecutive 
10min. hours (10 minutes Format: 0.1 = 10min., for example, 12.4 
= 12godz.40min., the counting takes place in the 0.1 ÷ 0.6 on the 
value of 0.6 is about 1 meter jump unit (hour).

OK

RESET

RESET

 MENU
 Format

 Format
   6 min.

 Format
 10 min.

Saved

   6 min.

Saved

 10 min.

OK

OK

p

q

Course  of  conduct  when  determining  the  rounding  off  is  as 
follows:
1) By button  MENU pass to main menu.
2) By buttons UP or DOWN select item     Menu -> Program and 
press button OK.
3) Then shows Menu -> Program included follow items:  
Program -> Loop  mode in which the counting time from zero 
up without regard to the setpoint. Meter measures the time until 
the meter overflows. 
Program -> To UP meter will be time to count up from zero to a 
specified (parameter Menu -> Threshold).
Program -> To DOWN  zliczanie realizowane będzie w dół, 
zaczynając od ustalonej wartości progowej (parameter Menu -
> Threshold), and ending with zero. By buttons UP and DOWN 
select correct option and press button  OK.. Enter of the 
selected option is indicated by displaying the message: Saved 
with the name of the selected parameter.

Proceedings in determining the time display format is as follows:
1) By button  MENU pass to main menu.
2) By buttons UP and DOWN select item   Menu -> Format and 
press OK. 
3) Then shows  Menu -> Format included follow items: 
Format -> 6min.
Format -> 10min.

 

By buttons UP and DOWN select correct option and press 
button OK. Enter  choosen option is indicated by disply 
message. Saved by the name of the selected parameter.
4) To exit the menu without saving the changes, at any time by 
editing press the RESET button

Menu -> Signal

Menu specifies the type of signal is connected to the input signal 
and gate reset. There are two options here, the signal stable (DC) 
and alternating signal (AC).

Menu -> Threshold

The threshold parameter determines the threshold which will be 
counted at the time of the selected program to the top, or from 
which starts the timer at the bottom on the chosen program. The 
threshold parameter has no effect on the work counter, where the 
program was chosen loop. Threshold can be set to the nearest 
full hour

Proceedings in determining the threshold value is as follows:
1) By button MENU pass to main menu.
2) By buttons UP or  DOWN select item  Menu -> Threshold and 
press button OK.. 
3) The bottom line will show the current setpoint. Edited currently 
digit is signaled by the pulsating cursor.

Menu -> Program

The menu allows you to specify whether the meter will be tracked 
from time zero to a preset threshold, counting from the threshold 
to zero, or tracked without any restrictions from zero upward until 
it reaches the counter overflow.

4) From edit mode you can move out by pressing the RESET 
button.  This  withdrawal  of  the  parent  menu  without  saving 
changes.

p

q

OK

Program

 MENU

OK

 Saved

 Program

OK

 Program

 Saved

OK

 Saved

 Program

RESET

 Loop

 Loop

 To Up

 To Up

 To Down

 To Down

RESET

000012

 Saved

MENU

p

q

+1

-1

"

MENU

OK

000000

OK

RESET

000012

Threshold

Threshold

Threshold

OK

RESET

RESET

Saved

 MENU

AC_50Hz

Saved
AC_50Hz

OK

OK

p

q

 MENU

 MENU

 Stable_DC

 Stable_DC

 SIGNAL

 SIGNAL

 SIGNAL

Содержание CLG-03

Страница 1: ...o reset the current cycle of meter The programming mode allows you to go back to the higher level menus If the RESET button is pressed while editing a parameter the program comes from the editing mode without saving changes OK FUNCTIONING Measurement of the duration of the high In this mode the user specifies a set value of time the meter counts all the time in which the input is given gates high ...

Страница 2: ...on or from the input signal is given zero Set value METER PULSES RESET JOINT ON START STOP START STOP SET VALUE METER PULSES RESET JOINT ON START STOP START STOP ATTENTION Meter retains its current state after turning off the power supply voltage This means that after re power the system restore all the settings are both meter and meter indication and relay output status Programming of meter Meter...

Страница 3: ...aved with the name of the selected parameter Proceedings in determining the time display format is as follows 1 By button MENU pass to main menu 2 By buttons UP and DOWN select item Menu Format and press OK 3 Then shows Menu Format included follow items Format 6min Format 10min By buttons UP and DOWN select correct option and press button OK Enter choosen option is indicated by disply message Save...

Страница 4: ...e 4 To exit the option to choose the language without any changes press the RESET button Menu Light This parameter allowsto specify a way of highlight a meter display You can set the highlight permanently highlight or highlighting only for 60 seconds after you press any button To determine how the highlight you need 1 Pass to menu by pressing a button MENU 2 By buttons UPor DOWN select Menu Light ...

Страница 5: ...authorised modifications are to be made in the relay otherwise the device may be damaged or malfunction which in turn may lead to damage of the protected engine and jeopardise its operators Should this warning be ignored the producer cannot be held responsible for any related events and is entitled to deem this warranty invalid in the case of any complaint External signal does not permanently remo...

Страница 6: ...tended for counting the number of working hours in automatic production processes or the number of device working hours which due to safety requirements and operation efficiency have limited overhaul life i e operational capacity that may notbeexceeded e g advancedpowerunits specialradioactivelamps etc ASSEMBLY FUNCTIONING CLG 13T meter is an electronic one way meter enabling the counting of worki...

Страница 7: ...non voltage type internal battery baterry life 5 years read input voltage 4 30V DC input RESET 4 30V DC display 6 characters h 6 7mm precision 1 1digit working temperature 10 40 C dimensions 48 24 52mm fixing hole 45 23mm TECHNICAL DATA U URESET Do not dispose of this device to a garbage bin with other unsorted waste In accordance with the Waste Electrical and Electronic Equipment Act any househol...

Страница 8: ... are intended for counting the number of working hours in automatic production processes or the number of device working hours which due to safety requirements and operation efficiency have limited overhaul life i e operational capacity that may not be exceeded e g advanced powerunits specialradioactivelamps etc CLG 14T meter is an electronic one way meter enabling the counting ofworkinghoursin0to...

Страница 9: ...terylife 5years counteriputvoltage 24VAC DC maximumcountigfrequency 200Hz RESETinput non voltagetype display 8characters h 6 7mm precision 1min working temperature 10 40 C dimensions 48 24 52mm 45 23mm fixing hole D141114 AC DC RESET 5 9 0 8 3 1 2 5 9 8 0 8 4 F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice phone fax 48 42 215 23 83 227 09 71 POLAND http www fif com pl e mail fif fif com...

Страница 10: ...0V AC DC 1 Disconnectthepowersupply 2 Slidethemountingbracketofffromthebodyofthecounter 3 Put the counter into the mounting hole insert the fastening metalplateandtightenthenut 4 Connect the L N voltage which is an indication of the controlled device operation to the terminals of the counting input D160309 L N Purpose Functioning WARRANTY The F F products are covered by a warranty of the 24 months...

Страница 11: ...the casing front panel control It consists of a two lines eight alphanumeric display and placed under it keyboard with five buttons 01304569 TOTAL Two lineseight alphanumeric display Control buttons CLI 01 RESET OK MENU p q Display present information about the current state of work and in programming mode allows the configuration of the meter parameters The buttons on the control panel perform th...

Страница 12: ...e of type signal for the RESET input 3 FiltrDC FiltrDC menu is used to define the parameters of the internal digital filter It can help reduce frequency counting pulses to the set value and thus reduce the possibility of wrong work of system caused by interference such as by contact vibration systems Diagram of the digital filter configuration is presented in the following picture 00000999 MENU TH...

Страница 13: ...s is possible by press the RESET button Filtr NO Filtr 2Hz Filtr 5Hz SAVED xxxxHz Filtr 500Hz Filtr 1000Hz RESET p q FiltrDC MENU OK OK After you select a menu FiltrDC press OK Then using the UP and DOWN buttons to select the appropriate frequency filtering and approve it OK Exit menu without saving changes is possible by pressing the RESET button Set the menu item in FiltrDC doesn t mean exclusio...

Страница 14: ...for counting AC DC voltage signals generated by additional peripheral devices in order to determine the number of carriedoutworkingcyclesinautomaticssystems e g inordertocontrol the number of press strokes the number of revolutions of a rotating device thenumberofcomponentsleavingtheproductionline etc Assembly Functioning CLI 11T meter is an electronic one way meter enabling the counting of pulses...

Страница 15: ...ry battery life 5 years read input voltage 110 240V AC DC max coting frequency 200Hz input RESET non voltage type display 8 characters h 6 7mm precision 1 1digit working temperature 10 40 C dimensions 48 24 52mm fixing hole 45 23mm TECHNICAL DATA U URESET 5 9 0 8 3 1 2 5 9 1 8 4 9 F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice phone fax 48 42 215 23 83 227 09 71 POLAND http www fif com...

Отзывы: