background image

PURPOSE

Pulse  meter  is  intended  for  counting  AC/DC  voltage  signals, 
generated by additional peripheral devices in order to determine 
the number of carried out working cycles in automatics systems, 
e.g. in order to control the number of press strokes, the number of 
revolutions  of  a  rotating  device,  the  number  of  components 
leaving the production line, etc. 

CLI-01

CLI-01

www.fif.com.pl

ul. Konstantynowska 79/81

tel/fax 48 42 2270971 POLAND

e-mail: [email protected]

95-200 Pabianice

F&F products are covered by an 24 months warranty from date of purchase

PULSE METER

   

METER FUNCTIONS

-  control  panel,  enabling  programming  and  the  monitoring  of 
device operation
-  T  input,  adapted  for  operation  with AC/DC  signal,  5  to  264V 
amplitude and 50 Hz frequency for AC and 5kHz for DC signals
-  possibility  to  set  THRESHOLD    parameter  (1÷99  999  999 
range),  specifying  the  limiting  number  of  pulses  counted  in  a 
single operation cycle 

- external RESET input
- relay output signaling the preset meter state (contact1C/O 8A) 
-  local  counter,  reset  using  the  external  reset  input  or  using 
RESET button
- total counter for all impulses (loop mode 0 

 99 999 999 

 0 

 ... 

or reset using the meter configuration menu) 
- digital filter, enabling the limiting of maximum frequency of the 
counted pulses (in order to reduce interferences on meter input) 
- local and total meter state memory after supply failure 
- program menu in three languages: Polish, English or Russian

5 9 0 8 3 1 2

5 9 1 7 6 4

Description of display and control panel

The services and programming meter CLI-01 is used mounted on the 
casing front panel control. It consists of a two lines, eight alphanumeric 
display, and placed  under it keyboard with five buttons.

01304569

TOTAL:

Two lineseight
alphanumeric display

Control
buttons

CLI-01

RESET

OK

MENU

p q

Display present information about the current state of work, and in 
programming mode allows the configuration of the meter 
parameters. The buttons on the control panel, perform the following 
functions:

MENU

Button functions:

MENU

 - pass to programming mode. In the cause that the meter 

is working in the editing parameter mode,  of a number, press this 
button to go to the next edition of the digits.

FUNCTIONING

Meter  CLI-01  is  a  one-way  meter  which  count  to  up.  Pulses  are 
counted from zero to a value set by the user. 

RESET

p

q

UP and DOWN - to select the next position of menu, and to 
increase or decrease value of editing parameter.

OK 

-

 

pass to choosen position of menu and to enter changes

RESET

  -  resetting  to  the  current  meter  cycle.  In 

programming  mode  allows  return  to  main  menu  If  the 
RESET button is pressed while editing a parameter, it go out 
from edit mode without saving  changes.

OK

SET VALUE

M

A

T

E

R

3sec

P

U

L

S

E

S

R

E

S

E

T

J

O

IN

T

ON.

Device status is indicated by messages on the display. During the 
counting of pulses on the display, see the following information:

00000999

 

>>

Status of transformer 
output
(open joint)

Signalization 

read of pulses

Actual 
reports of meter

Signalization 

work of meter

The achievement of the set value is indicated by closure of relay 
joints. At the same time stops counting pulses, the illumination of 
display blinking three times, and the display shows the message 
STOP.

00002000

 

STOP

Actual and set 
value of meter

Signalizaton achievement

of the set value

Status of transformer 
output
(open joint)

Содержание CLG-03

Страница 1: ...o reset the current cycle of meter The programming mode allows you to go back to the higher level menus If the RESET button is pressed while editing a parameter the program comes from the editing mode without saving changes OK FUNCTIONING Measurement of the duration of the high In this mode the user specifies a set value of time the meter counts all the time in which the input is given gates high ...

Страница 2: ...on or from the input signal is given zero Set value METER PULSES RESET JOINT ON START STOP START STOP SET VALUE METER PULSES RESET JOINT ON START STOP START STOP ATTENTION Meter retains its current state after turning off the power supply voltage This means that after re power the system restore all the settings are both meter and meter indication and relay output status Programming of meter Meter...

Страница 3: ...aved with the name of the selected parameter Proceedings in determining the time display format is as follows 1 By button MENU pass to main menu 2 By buttons UP and DOWN select item Menu Format and press OK 3 Then shows Menu Format included follow items Format 6min Format 10min By buttons UP and DOWN select correct option and press button OK Enter choosen option is indicated by disply message Save...

Страница 4: ...e 4 To exit the option to choose the language without any changes press the RESET button Menu Light This parameter allowsto specify a way of highlight a meter display You can set the highlight permanently highlight or highlighting only for 60 seconds after you press any button To determine how the highlight you need 1 Pass to menu by pressing a button MENU 2 By buttons UPor DOWN select Menu Light ...

Страница 5: ...authorised modifications are to be made in the relay otherwise the device may be damaged or malfunction which in turn may lead to damage of the protected engine and jeopardise its operators Should this warning be ignored the producer cannot be held responsible for any related events and is entitled to deem this warranty invalid in the case of any complaint External signal does not permanently remo...

Страница 6: ...tended for counting the number of working hours in automatic production processes or the number of device working hours which due to safety requirements and operation efficiency have limited overhaul life i e operational capacity that may notbeexceeded e g advancedpowerunits specialradioactivelamps etc ASSEMBLY FUNCTIONING CLG 13T meter is an electronic one way meter enabling the counting of worki...

Страница 7: ...non voltage type internal battery baterry life 5 years read input voltage 4 30V DC input RESET 4 30V DC display 6 characters h 6 7mm precision 1 1digit working temperature 10 40 C dimensions 48 24 52mm fixing hole 45 23mm TECHNICAL DATA U URESET Do not dispose of this device to a garbage bin with other unsorted waste In accordance with the Waste Electrical and Electronic Equipment Act any househol...

Страница 8: ... are intended for counting the number of working hours in automatic production processes or the number of device working hours which due to safety requirements and operation efficiency have limited overhaul life i e operational capacity that may not be exceeded e g advanced powerunits specialradioactivelamps etc CLG 14T meter is an electronic one way meter enabling the counting ofworkinghoursin0to...

Страница 9: ...terylife 5years counteriputvoltage 24VAC DC maximumcountigfrequency 200Hz RESETinput non voltagetype display 8characters h 6 7mm precision 1min working temperature 10 40 C dimensions 48 24 52mm 45 23mm fixing hole D141114 AC DC RESET 5 9 0 8 3 1 2 5 9 8 0 8 4 F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice phone fax 48 42 215 23 83 227 09 71 POLAND http www fif com pl e mail fif fif com...

Страница 10: ...0V AC DC 1 Disconnectthepowersupply 2 Slidethemountingbracketofffromthebodyofthecounter 3 Put the counter into the mounting hole insert the fastening metalplateandtightenthenut 4 Connect the L N voltage which is an indication of the controlled device operation to the terminals of the counting input D160309 L N Purpose Functioning WARRANTY The F F products are covered by a warranty of the 24 months...

Страница 11: ...the casing front panel control It consists of a two lines eight alphanumeric display and placed under it keyboard with five buttons 01304569 TOTAL Two lineseight alphanumeric display Control buttons CLI 01 RESET OK MENU p q Display present information about the current state of work and in programming mode allows the configuration of the meter parameters The buttons on the control panel perform th...

Страница 12: ...e of type signal for the RESET input 3 FiltrDC FiltrDC menu is used to define the parameters of the internal digital filter It can help reduce frequency counting pulses to the set value and thus reduce the possibility of wrong work of system caused by interference such as by contact vibration systems Diagram of the digital filter configuration is presented in the following picture 00000999 MENU TH...

Страница 13: ...s is possible by press the RESET button Filtr NO Filtr 2Hz Filtr 5Hz SAVED xxxxHz Filtr 500Hz Filtr 1000Hz RESET p q FiltrDC MENU OK OK After you select a menu FiltrDC press OK Then using the UP and DOWN buttons to select the appropriate frequency filtering and approve it OK Exit menu without saving changes is possible by pressing the RESET button Set the menu item in FiltrDC doesn t mean exclusio...

Страница 14: ...for counting AC DC voltage signals generated by additional peripheral devices in order to determine the number of carriedoutworkingcyclesinautomaticssystems e g inordertocontrol the number of press strokes the number of revolutions of a rotating device thenumberofcomponentsleavingtheproductionline etc Assembly Functioning CLI 11T meter is an electronic one way meter enabling the counting of pulses...

Страница 15: ...ry battery life 5 years read input voltage 110 240V AC DC max coting frequency 200Hz input RESET non voltage type display 8 characters h 6 7mm precision 1 1digit working temperature 10 40 C dimensions 48 24 52mm fixing hole 45 23mm TECHNICAL DATA U URESET 5 9 0 8 3 1 2 5 9 1 8 4 9 F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice phone fax 48 42 215 23 83 227 09 71 POLAND http www fif com...

Отзывы: