background image

- 1 -

- 2 -

PURPOSE

Pulse meter is intended for counting AC/DC voltage signals, generated 
by additional peripheral devices in order to determine the number of 
carried out working cycles in automatics systems, e.g. in order to control 
the number of press strokes, the number of revolutions of a rotating 
device, the number of components leaving the production line, etc. 

ASSEMBLY

FUNCTIONING

CLI-11T meter is an electronic, one-way meter, enabling the counting of 
pulses from 0 to 999999 range (six   digits ). It is equipped with RESET 
input for the connection of external button and RESET   input for the 
connection of an external button, enabling the resetting of the meter 
state for any value.

1. Take OFF the power.

2. Unscrew the nut and remove the attachment plate. 
3. Embed meter 

 in the 

assembly hole, attach plate and tighten the cap 

screws. 
4. T

o joints

 U (

read 

input

)   connect the voltage 

which is reading signal

 

(impulse)

.

5. 

To 

RESET 

joints 

 connect 

monostabile close button. ATTENTION! Do 

not connect any voltage.

.

WIRING DIAGRAM

D141121

supply (non-voltage type)

internal battery

battery life

5 years

read input voltage

110÷240V AC/DC

max coting frequency

200Hz

input RESET

non-voltage type

display

8 characters / h=6,7mm

precision

1%±1digit)

working temperature

-10÷40°C

dimensions

48×24×52mm

fixing hole

45×23mm

TECHNICAL DATA

U

U

RESET

+

+

5

9 0 8 3 1 2

5 9 1 8 4 9

F&F Filipowski sp. j.

Konstantynowska 79/81   95-200 Pabianice   

phone/fax: (+48 42) 215 23 83 / 227 09 71    POLAND

http://www.fif.com.pl   e-mail: [email protected]

PULSE METER

Do not dispose of this device to a garbage bin with other unsorted waste! 

In  accordance  with  the  Waste  Electrical  and  Electronic  Equipment  Act 
any  household  electro-waste    can  be  turned  in  free  of  charge  and  in  any 
quantity to a collection point established for this purpose, as well as to the 
store in the event of purchasing new equipment (as per the old for new rule, 
regardless of brand). Electro-waste thrown in the garbage bin or abandoned 
in the

 

bosom of nature pose a threat to the environment and human health.

CLI-11T

230V

WARRANTY.

  The  F&F  products  are 

covered by a warranty of the 24 months   
from the date of purchase.  Effective only 
with  proof  of  purchase.  Contact  your 
dealeror  directly  with  us.  More 
information how to make a compliant can 
be found on the website:
www.fif.com.pl/reklamacje

Содержание CLG-03

Страница 1: ...o reset the current cycle of meter The programming mode allows you to go back to the higher level menus If the RESET button is pressed while editing a parameter the program comes from the editing mode without saving changes OK FUNCTIONING Measurement of the duration of the high In this mode the user specifies a set value of time the meter counts all the time in which the input is given gates high ...

Страница 2: ...on or from the input signal is given zero Set value METER PULSES RESET JOINT ON START STOP START STOP SET VALUE METER PULSES RESET JOINT ON START STOP START STOP ATTENTION Meter retains its current state after turning off the power supply voltage This means that after re power the system restore all the settings are both meter and meter indication and relay output status Programming of meter Meter...

Страница 3: ...aved with the name of the selected parameter Proceedings in determining the time display format is as follows 1 By button MENU pass to main menu 2 By buttons UP and DOWN select item Menu Format and press OK 3 Then shows Menu Format included follow items Format 6min Format 10min By buttons UP and DOWN select correct option and press button OK Enter choosen option is indicated by disply message Save...

Страница 4: ...e 4 To exit the option to choose the language without any changes press the RESET button Menu Light This parameter allowsto specify a way of highlight a meter display You can set the highlight permanently highlight or highlighting only for 60 seconds after you press any button To determine how the highlight you need 1 Pass to menu by pressing a button MENU 2 By buttons UPor DOWN select Menu Light ...

Страница 5: ...authorised modifications are to be made in the relay otherwise the device may be damaged or malfunction which in turn may lead to damage of the protected engine and jeopardise its operators Should this warning be ignored the producer cannot be held responsible for any related events and is entitled to deem this warranty invalid in the case of any complaint External signal does not permanently remo...

Страница 6: ...tended for counting the number of working hours in automatic production processes or the number of device working hours which due to safety requirements and operation efficiency have limited overhaul life i e operational capacity that may notbeexceeded e g advancedpowerunits specialradioactivelamps etc ASSEMBLY FUNCTIONING CLG 13T meter is an electronic one way meter enabling the counting of worki...

Страница 7: ...non voltage type internal battery baterry life 5 years read input voltage 4 30V DC input RESET 4 30V DC display 6 characters h 6 7mm precision 1 1digit working temperature 10 40 C dimensions 48 24 52mm fixing hole 45 23mm TECHNICAL DATA U URESET Do not dispose of this device to a garbage bin with other unsorted waste In accordance with the Waste Electrical and Electronic Equipment Act any househol...

Страница 8: ... are intended for counting the number of working hours in automatic production processes or the number of device working hours which due to safety requirements and operation efficiency have limited overhaul life i e operational capacity that may not be exceeded e g advanced powerunits specialradioactivelamps etc CLG 14T meter is an electronic one way meter enabling the counting ofworkinghoursin0to...

Страница 9: ...terylife 5years counteriputvoltage 24VAC DC maximumcountigfrequency 200Hz RESETinput non voltagetype display 8characters h 6 7mm precision 1min working temperature 10 40 C dimensions 48 24 52mm 45 23mm fixing hole D141114 AC DC RESET 5 9 0 8 3 1 2 5 9 8 0 8 4 F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice phone fax 48 42 215 23 83 227 09 71 POLAND http www fif com pl e mail fif fif com...

Страница 10: ...0V AC DC 1 Disconnectthepowersupply 2 Slidethemountingbracketofffromthebodyofthecounter 3 Put the counter into the mounting hole insert the fastening metalplateandtightenthenut 4 Connect the L N voltage which is an indication of the controlled device operation to the terminals of the counting input D160309 L N Purpose Functioning WARRANTY The F F products are covered by a warranty of the 24 months...

Страница 11: ...the casing front panel control It consists of a two lines eight alphanumeric display and placed under it keyboard with five buttons 01304569 TOTAL Two lineseight alphanumeric display Control buttons CLI 01 RESET OK MENU p q Display present information about the current state of work and in programming mode allows the configuration of the meter parameters The buttons on the control panel perform th...

Страница 12: ...e of type signal for the RESET input 3 FiltrDC FiltrDC menu is used to define the parameters of the internal digital filter It can help reduce frequency counting pulses to the set value and thus reduce the possibility of wrong work of system caused by interference such as by contact vibration systems Diagram of the digital filter configuration is presented in the following picture 00000999 MENU TH...

Страница 13: ...s is possible by press the RESET button Filtr NO Filtr 2Hz Filtr 5Hz SAVED xxxxHz Filtr 500Hz Filtr 1000Hz RESET p q FiltrDC MENU OK OK After you select a menu FiltrDC press OK Then using the UP and DOWN buttons to select the appropriate frequency filtering and approve it OK Exit menu without saving changes is possible by pressing the RESET button Set the menu item in FiltrDC doesn t mean exclusio...

Страница 14: ...for counting AC DC voltage signals generated by additional peripheral devices in order to determine the number of carriedoutworkingcyclesinautomaticssystems e g inordertocontrol the number of press strokes the number of revolutions of a rotating device thenumberofcomponentsleavingtheproductionline etc Assembly Functioning CLI 11T meter is an electronic one way meter enabling the counting of pulses...

Страница 15: ...ry battery life 5 years read input voltage 110 240V AC DC max coting frequency 200Hz input RESET non voltage type display 8 characters h 6 7mm precision 1 1digit working temperature 10 40 C dimensions 48 24 52mm fixing hole 45 23mm TECHNICAL DATA U URESET 5 9 0 8 3 1 2 5 9 1 8 4 9 F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice phone fax 48 42 215 23 83 227 09 71 POLAND http www fif com...

Отзывы: