PURPOSE
FUNCTIONS
CLG-03 is a programmable, multi-function electronic meter,
enabling the counting of working hours of the connected devices
or systems in 1 to 999 999 range, corresponding to 114 years of
operation. Working time is counted according to an individual
program, set by the user. After reaching the limiting value, the
meter will configure itself according to individual user's needs.
CLG-03
CLG-03
www.fif.com.pl
F&F products are covered by an 24 months warranty from date of purchase
WORKING TIME METERS
- control panel, enabling programming and the monitoring of
device operation
- T input for DC signal and AC signal 50 Hz
- counting time upwards without threshold value
- 'downward' counting mode to the selected value with zero value
F&F Filipowski sp. j
ul. Konstantynowska 79/81
tel/fax 48 42 2270971
e-mail: [email protected]
95-200 Pabianice POLAND
5 9 0 8 3 1 2 5 9 1 8 3 2
Deescription of display and control panel
For operating and programming the meter CLG-03 is used mounted on
the front control panel . It consists of a double, eight-digit alphanumeric
display, and placed underneath the five key keyboard
Two rows
alphanumeric
eight-digit display
Control
buttons
CLG-03
000004.6
>>
RESET
OK
MENU
p q
- counting working time with high state (constant voltage) at the T
input
- counting working time between two pulses given at the T
input
-counting time upwards to the selected threshold value
- external RESET input
- relay output signaling the preset meter state (contact1C/O 8A )
- relay action selection: pulse with set time length; ON
→
OFF or
OFF
→
ON state change
- local and total meter state memory after supply failure
- limiting access to program menu using PIN code- setting
display illumination mode
- program menu in three languages: Polish, English or Russian
Work of meter is indicayed by pulsating symbol >> located in the
top row. Measurement of time is symbolized by appearing in the
right corner of the upper line of the symbol clock. On the left side
there is a symbol representing the state of output relay
RESET
p
q
UP
and
DÓWN
- to move between each menu items, and to
increase or decrease the value of the parameter being
edited.
OK
-
entrance to the selected menu item, and enter
changes.
RESET
- to reset the current cycle of meter. The
programming mode allows you to go back to the higher-level
menus. If the RESET button is pressed while editing a
parameter, the program comes from the editing mode
without saving changes.
OK
FUNCTIONING
Measurement of the duration of the high
In this mode, the user specifies a set value of time the meter
counts all the time in which the input is given gates high state. The
emergence of the low mileage makes the freeze, and it will restart
when the input again appears high state. Achieving the set value
is indicated by a change in the relay outputs (NO contact
closure), and stop counting the time. At the same time the display
shows STOP and highlighting the display flashes three times.
Start a new cycle is possible only after the timer expires, the level
of the control panel (by pressing the RESET button), or via an
external reset input. To protect the system against accidental
erasure of the meter, a zero signal is activated only after three
seconds after you press the RESET button or the input signal is
given for reseting. This does not include the loop mode, where
the reset is only possible through an external signal to a reset,
and the pulse duration can not be less than ten seconds.
MENU
Signalization
of measurement of time
000012.4
>>
State of relay output
(open joint)
Current
reports of meter
Signalization
of meter work
After reaching the set value until the display shows STOP
message, and highlighting the display flashes three times. This
situation is shown in the figure below.
00006.0
STOP
Ending value
of meter
Signaling to achieve
a set value
State
of relay output
(close joint)
After the entry into programming mode the meter, through the
display and clear the configuration menu, you can easily set all
the parameters of the meter.
Button functions
MENU
- to move the programming mode of the system. If the
meter is in edit mode of numeric parameter, press the button
to jump to the next edition of the numb
The bottom line of the display is an indication of the current meter.
The unit is meter hours. Digit after the decimal point, depending
on the format, might indicate tenths of hours (6min Format: 0.1 =
6min., For example, 12.4 = 12godz.24min.) Or counted the
number of consecutive 10min. hours (10 minutes Format: 0.1 =
10min., for example, 12.4 = 12godz.40min., but when counting
takes place in the 0.1 ÷ 0.6 on the value of 0.6 is about 1 meter
jump unit (hour).