Manual FältCom ECII SE Eng
Page 33 of 36
11 Programming Key Map
In order for the emergency telephone to be programmed it has to be:
1) connected to the telephone line
2) be connected to the alarm button, and
3) be set to programming mode. It is assumed that an alarm button with breaking
function is used.
Programming can be initiated approximately 20 sec. after the telephone has been connected
to the telephone line. Upon completion of each programming sequence a 4-tone confirms that
the telephone has accepted the programming. If no button is pushed during a time lapse of 30
sec. programming mode is automatically deactivated.
Below follows an overview of all programmable functions in FältCom ECII SE. In the column
to the right are the possible normal values marked with “X” or shown with the actual value.
The only programming sequence that is an absolute must to make it possible to make an
alarm is marked with a gray color in the table below.
No. Programming
sequence
Function
Def
1.
< Phone No. >
Programming of phone number to
primary alarm receiver. Max 20 digits
2.
< Phone No. >
Programming of phone number to
secondary alarm receiver. Max 20
digits
3.
Test of secondary alarm receiver
4.
< Alarm code 1 >
Programming of alarm code 1. Max
10 digits
5.
< Alarm code 2 >
Programming of alarm code 2. Max
10 digits.
6.
< 3-6 >
< Phone No. >
Programming of phone numbers to
alarm receiver 3 to 6. Max 20 digits
7.
< 3-6 >
Test of alarm receiver 3 to 6.
8.
Sets alarm button input to Normally
Open
9.
Sets alarm button input to Normally
Close
X
10.
Activation of dial tone detection
11.
Deactivation of dial tone detection
X