Manual FältCom ECII SE Eng
Page 22 of 36
alarm function is active the first test alarm is sent 2 minutes after exiting programming mode.
After that the test alarms is sent every N x 24 hours where N is the test alarm interval in days.
Note that the lift phone counter is reset at every time programming mode is entered and when
the power is disconnected from the lift phone.
1.
Select the required test interval: 1 to 9 days. (Use a digit between 1 and 9.)
<Days (1 – 9)>
2.
Enter the telephone number of the test alarm receiver
<Area code + telephone number (max 20 digits)>
3.
Enter alarm code for the test alarm:
<Code (max 10 digits)>
4.
To check the test alarm function:
When testing a test alarm all communication tones (DTMF) are played out in the lift phone
speaker which makes it possible to hear that the test alarm is being transmitted. Note that the
test alarm is dialed out 1 minute after exiting of programming mode.
Press the following sequence to delete the function automatic test alarm:
If a test alarm is failed the next attempt is done after 10 minutes. Totally 10 attempts are
done.
7.2.5 Answering
function
It is possible to make a telephone call the lift and have a conversation with the trapped
person. Normally this function is on but it can be deactivated.
1.
Press the following sequence to deactivate the function:
2.
Press the following sequence to activate the function:
With two or more FältCom ECII SE on the same telephone line, one of them is programmed
as the master with ID number ”1”. The others are coded with their individual number (2-6) by
replacing the digit
with the corresponding digit.
Example:
for lift phone 2 in the chain.
For best sound quality all lift phones should be connected in series, not in parallel. The last lift
phone in the series is given identity ”1”. A total of maximum six lift/emergency phones may be
connected on the same telephone line.
See also section
Calls to a lift phone
for more information about call the FältCom ECII SE.