Manual FältCom ECII SE Eng
Page 32 of 36
10 Technical data
Supply voltage:
(Single mounted)
None, if line voltage is higher than 32 VDC. If line voltage is
between 20 VDC and 32 VDC an external power supply is
required. This level can be even lower if the lift phone is
mounted on an internal exchange (PABX). By mounting the
attached jumper FältCom ECII SE will work without external
power supply down to 22 VDC. If also an external power
supply is connected together with the jumper the lift phone
will work down to 12 VDC. When the jumper is mounted
FältCom ECII SE is not allowed to be connected to the public
switched telephone network (PSTN).
Supply voltage:
(2-6 units on the same line)
If several lift phones are connected to the same telephone
line an external power supply always is required for each
unit. The line voltage must also be higher than 20 VDC
because of the line detection function of occupied line. See
more under section
Busy line function
Current consumption:
At rest:
25-45 uA
Nominal:
12-60 mA
Ext. power supply:
4-16 mA
Indications:
Yellow and green LED during alarm
Sound and light indication when programming
Test alarm:
1 time/day up to once every 9 days (selectable on/off)
Alarm receiver types:
Contact your local distributor for information about alarm
centrals that can handle CPC protocol.
All tone selection telephones, including mobile phones, can
also be used as alarm receivers
Protocol:
CPC
&
P100
Speech exchange:
Duplex or simplex
Signaling:
DTMF
Calling:
Tone
selection
Answering function:
Automatic (selectable on/off)
Casing:
Stainless sheet steel 1.5 mm. Vandal proof.
Dimensions HxWxD:
100 x 100 x 23 mm (with frame)
105 x 90 x 26 mm (behind COP)
180 x 125 x 25 mm (with frame and alarm button = ALBU)
Weight:
235 gram (with frame)
187 gram (behind COP)
310 gram (with frame and alarm button = ALBU)