5.2.3  Programming and testing 

On the back of the lift phone, there is a keypad used for programming call numbers, function 
selection, and testing. All such settings are made during the installation and, normally, no 
subsequent changes are required. It is also possible to remotely program the lift phone with a 
special Windows program and a modem. Contact your local distributor for more information. 

The FältCom ECII SE is capable of calling 6 alarm receivers or standard telephones with tone 
selection. 
 
The lift phone can be programmed to send a test alarm to a specific test alarm receiver with 
an interval of 1–9 days. This alarm tests the lift-phone electronics and the telephone line. 
 
The lift phone can also be programmed to answer an incoming call automatically after four 
ringing signals. In this case, tones are heard in the receiver when the call is connected. 
 
If an emergency power supply is connected, the lift phone automatically can send an alarm if 
the battery is bad and need to be replaced. A special telephone number for the battery alarm 
can be programmed. 
 
See 

Programming

 section for detailed programming instructions. 

6 Installation 

instructions 

Only competent and qualified personnel may install the FältCom ECII SE. Knowledge, 
technical skill and correct equipment are required for safe and efficient installation.

 

Mind your own safety when installing FältCom ECII SE. You must never work in an 
open lift shaft without a safety harness. Be extremely careful and break current if 
you work close to a voltage of 230-400V, e.g. in the lift engine room. Never 
disconnect a cable before you have made sure that it is not connected to any 
voltage 

Start by selecting a suitable place for the lift phone. Usually, you can find an easily accessible 
and yet well protected place in the lift cage ceiling. Avoid installing the phone in a corner or 
behind anything that may reflect the sound. Such installation might lead to acoustic feedback 
instability between the loudspeaker and the microphone. You must be able to access the 
existing suspension cable and the alarm button in the lift. Also, keep in mind that you must be 
able to access the back of the lift phone in order to connect cables and program different 
functions. Normally, this is easier to do inside of the lift, before the lift phone is screw-
mounted.  

Make sure that you will not saw or drill in existing cabling when you make the holes!

 

6.1 Recessed 

mounting 

1.  

Select a suitable place according to the instructions above. 

2.  

Drill a hole in the centre of the selected place and then make a hole with a 86-mm 
rotary hole saw or drill. See the enclosed drill template. 

Содержание ECII SE

Страница 1: ...Manual F ltCom ECII SE Eng Page 1 of 36 Version 5 2 Updated 2006 10 25 F ltCom ECII SE Manual and installation instructions...

Страница 2: ...ing alarm button function 6 6 4 2 Separate alarm button s 6 6 5 Connection to telephone line 6 6 5 1 Connection to telephone exchange and other devices 6 6 5 2 Connection with separate suspension cabl...

Страница 3: ...tone detection 6 8 ALARM RECEIVING 6 8 1 Alarm call 6 8 1 1 Acknowledging an alarm 6 8 1 2 Speech exchange 6 8 1 3 Termination of active alarm mode 6 8 1 4 Forwarding a call 6 8 2 Calls to a lift pho...

Страница 4: ...lations that is evident of directive 1999 5 EG and the following standards Emission EN50801 1 EN12015 Immunity EN50082 1 EN120016 Telecom TBR21 The equipment has been approved in accordance with Counc...

Страница 5: ...ons Contact information www faltcom com 3 4 Repair return procedure F lt Communications AB only accepts returns which are accompanied by a completed Service Card which can be found in the section Serv...

Страница 6: ...Manual F ltCom ECII SE Eng Page 6 of 36 3 4 1 Service form...

Страница 7: ...Manual F ltCom ECII SE Eng Page 7 of 36...

Страница 8: ...e Art No 2019 Mounting Kit ECII Art No 2022 ECII Sticker Art No 2014 SE Programming Guide 4 1 1 System components There are a large variety of available system components that can be ordered separatel...

Страница 9: ...other predefined alarm receiver and indicates where the alarm comes from At the same time voice communication is established and the person in distress can talk to the staff at the alarm centre from w...

Страница 10: ...epared space behind the plate There is a version of the lift phone with a completely flat panel specially intended for such mounting Contact your local distributor for more information The connection...

Страница 11: ...ly to the lift phones The lift phone outlet marked DC is then connected to the existing emergency power supply of the lift via a special DC DC converter If no power supply is available a separate emer...

Страница 12: ...sonnel may install the F ltCom ECII SE Knowledge technical skill and correct equipment are required for safe and efficient installation Mind your own safety when installing F ltCom ECII SE You must ne...

Страница 13: ...e for a lift phone behind the button display plate There is a special version of the lift phone which is specially designed for mounting behind a button display plate Since the design of the display m...

Страница 14: ...inal adaptor To minimize disturbances when more than one F ltCom ECII SE is connected to the same telephone line it is recommended that they are connected in series not in parallel If the lift phone i...

Страница 15: ...ift phone Note that the cable brackets included in the mounting kit must be used in order to guarantee the function The combined wall and lift cage brackets comprise bracket screw washer and cable tie...

Страница 16: ...gle mounted lift phone by mounting the attached jumper marked J1 next to the green screw connector Then the lift phone can be used without a separate power supply down to 22 VDC Note that when the jum...

Страница 17: ...e loop amplifier The loop amplifier must work during power failure Connect it to a power supply that is working during power failures 6 8 Connection of external pictogram It is possible to connect ext...

Страница 18: ...functions Programming Starts and end of an all programming sequences Sequence receiver Used when programming more than 2 alarm receivers Alarm receiver 1 Phone number to alarm receiver 1 Alarm receiv...

Страница 19: ...ter about 10 seconds you will automatically enter programming mode The green LED will flash as long as the F ltCom ECII SE is in programming mode Programming mode is deactivated automatically after 30...

Страница 20: ...in the loudspeaker when an attempt is made to send a test alarm 7 1 4 Closing alarm button function Breaking function is default If the lift phone version with integrated alarm button is used it is a...

Страница 21: ...The waiting time is increased if you press two or more times Every pressing increases the waiting time by 2 seconds The primary alarm number for example is programmed as follows Area code subscriber n...

Страница 22: ...exiting of programming mode Press the following sequence to delete the function automatic test alarm If a test alarm is failed the next attempt is done after 10 minutes Totally 10 attempts are done 7...

Страница 23: ...ft phone will be closed for incoming calls until a new alarm is triggered To activate the alarm mode the following conditions must be fulfilled Alarm mode function is programmed A lift alarm has been...

Страница 24: ...ust be connected to external power Press the following sequence to activate the function And the following to deactivate the function The function needs a line voltage of minimum 20 VDC to work If the...

Страница 25: ...ect is reset to 180 seconds The button has no function at all There will be no possibility to change to simplex mode Note The lift phone will only make one attempt and it will only call the first alar...

Страница 26: ...call procedure for alarm receiver 2 when alarm receiver 1 is occupied This is done with the following programming sequence Country code 1 6 The function is disconnected with 7 2 10 2 Automatic disconn...

Страница 27: ...d 99 To restore the alarm type to the default value enter Note that F ltCom ECII SE always assumes that the programmed alarm type is speech connecting 7 2 13 Unit ID When a standard telephone is used...

Страница 28: ...e lift phone To do this programming mode is entered and a special function is activated One minute after termination of programming mode the lift phone will make a speech alarm with the alarm type 28d...

Страница 29: ...a way that makes everyone aware of the possibility of alarm calls In addition special functions for specific telephone keys should be clearly marked You cannot be sure that a manual will be readily a...

Страница 30: ...e you can finish it by pressing the key 5 TERMINATE ALARM MODE The call is automatically disconnected 8 1 4 Forwarding a call If you want to forward the alarm to the next alarm receiver press 2 FORWAR...

Страница 31: ...function can be deactivated The alternative is to connect external power to the lift phone 4 If it takes long time before the dial tone is heard the lift phone might start to early dialing out the te...

Страница 32: ...unit The line voltage must also be higher than 20 VDC because of the line detection function of occupied line See more under section Busy line function Current consumption At rest 25 45 uA Nominal 12...

Страница 33: ...om ECII SE In the column to the right are the possible normal values marked with X or shown with the actual value The only programming sequence that is an absolute must to make it possible to make an...

Страница 34: ...of active alarm mode 20 Deactivation of active alarm mode X 21 Activation of busy line function 22 Deactivation of busy line function X 23 Phone No Phone number to test alarm receiver Max 20 digits 2...

Страница 35: ...mmable alarm type for lift alarm Can be from 00d to 99d 10d 39 Reset of alarm type for lift alarm to 10d X 40 Activation of end of alarm 41 larmtyp Change of alarm type for end of alarm 28d 42 Activat...

Страница 36: ...den Support 46 0 90 18 39 27 or via e mail ec2 support faltcom se Phone 46 0 90 18 39 00 exchange Fax 46 0 90 18 39 29 Homepage www faltcom com Service address F lt Communications AB c o BL Elektronik...

Отзывы: