Manual FältCom ECII SE Eng
Page 18 of 36
7 Programming
All programming i.e. alarm numbers, codes to be sent and various function selections is done
with the keypad on the back of the speech unit. For practical and ergonomically reasons it is
recommended that all programming is done at (e.g. at a desk) before the FältCom ECII SE is
mounted in the lift. All programming remains in the lift phone also after it is disconnected from
the telephone line.
The keys on the keyboard have the following functions:
Programming
– Starts and end of an all programming sequences.
Sequence receiver –
Used when programming more than 2 alarm receivers.
Alarm receiver 1 –
Phone number to alarm receiver 1
Alarm receiver 2 –
Phone number to alarm receiver 2
Alarm code 1 –
Used for alarm receiver 1, 3, 4, 5 and 6
Alarm code 2 –
Used for alarm receiver 2
The other keys have the same function as on a standard telephone.
At each time the keys are depressed in programming mode a short tone is heard and after
each programming sequence, there is a 4-tone for successful and a 1-tone for unsuccessful
programming.
The FältCom ECII SE can also be programmed remotely. Contact your local distributor for
more information.