8
6) Fryer premix fan will run and spark ignition may be heard before unit locks out.
7) A neon will illuminate to indicate that lockout has occurred and that no burner flame is present.
8) Turn on gas supply.
9) Press lockout reset switch. See Figure 4
(Lock out indicator will extinguish).
10) Burner will ignite and heat indicator will illuminate to signify that burner is on.
Note
: If lockout should occur, repeat Steps 9 -10 until air is bled from supply.
2.5.1 Checking Controller Operation
To check operation of controls, refer to
“Appliance controls” - Section 6.1.
2.5.2 Checking Oil Filtration Pump
To check operation of oil filtration pump, refer to Section 7.
Important
After installation, the responsible technician should check for gas leaks and ensure the appliance is operating safely and
satisfactorily before handing over to the user.
2.6 TEMPERATURE LIMIT THERMOSTAT
The unit is equipped with an additional temperature limit thermostat, independent of the main controller.
In the case of operating thermostat failure, allowing oil temperature to rise above predetermined legislation safe
zone
(230
⁰
C)
, limit device will activate and cut power to controller. It will also stop the flow of gas to burner.
To re-set temperature limit thermostat, refer to Figure 4.
G2844F and G2845F Models
1) Turn burner and temperature controls ON/OFF switch to OFF position.
2) Allow oil to cool below 180
⁰
C
3) Reset red button on limit thermostat with a pen or similar item. The button is located behind cabinet door at
upper RH, below facia panel.
4) Turn burner and temperature controls ON/OFF switch to ON position.
5) Reselect temperature.
6) If limit thermostat reactivates carry out fault finding on temperature control circuitry.
2.7 INSTRUCTION TO USER
After installing and commissioning appliance, please hand Instructions to user or purchaser and ensure that the
person
(s)
responsible understands the instructions to correctly operate and clean unit in a safe manner.
Emphasis should be given to safe operation and use of drain valve and oil bucket. Oil bucket should not be
overfilled to allow safe movement. Oil should be allowed to cool before any manual handling.
Note:
The oil container may be heavy. Drain small amounts at a time if necessary, before lifting container. Manual
handling regulations should be observed.
Weight of Empty oil filter
– 4.25kg
Each litre of oil
– approx 1kg.
It is important to ensure that location of gas shutoff valve is made known to user and that procedure for operation in
an emergency be demonstrated.