Morsettiera
Terminal strip
%RvWHjERUQHV
Klemmleiste
Bornera
Quadro de bornes
&DYR&DEOH&kEOH
Kabel - Cable - Cabo
Collegamento a stella (trifase con neutro)
Star connection (three-phase with neutral wire)
Branchement étoile (triphasé avec neutre)
Sternanschluss (dreiphasig, ohne neutralen Leiter)
&RQH[LyQGHHVWUHOODWULIiVLFDFRQQHXWUR
&RQH[mRHPHVWUHODWULIiVLFRFRPQHXWUR
Collegamento a triangolo (trifase senza neutro)
Triangle connection (three-phase without neutral wire)
Branchement triangle (triphasé sans neutre)
Dreiecksanschluss (dreiphasig, ohne neutralen Leiter)
&RQH[LyQGHWULiQJXORWULIiVLFDVLQQHXWUR
&RQH[mRHPWULkQJXORWULIiVLFRVHPQHXWUR
Ponticello
Bridge
Pontet
Brücke
Puente
Shunt
$77(1=,21(1HOFDVRGLFROOHJDPHQWLWULIDVHVHQ]DQHXWURRPRQRIDVHLOFDYRGLDOLPHQWD]LRQHHOHWWULFDGHYH
essere sostituito.
:$51,1*,QWKHHYHQWRIDWKUHHSKDVHFRQQHFWLRQZLWKRXWDQHXWUDOZLUHRUDVLQJOHSKDVHFRQQHFWLRQWKH
electric cable must be replaced.
ATTENTION! Dans le cas de branchements triphasés sans neutre ou monophasé, le câble d’alimentation électrique
doit être remplacé.
ZU BEACHTEN: Bei dreiphasigem Anschluß ohne neutralen Leiter sowie bei einphasigem Anschluß muß das
1HW]NDEHODXVJHWDXVFKWZHUGHQ
£$7(1&,Ï1 (Q HO FDVR GH FRQH[LRQHV WULIiVLFDV VLQ QHXWUR R PRQRIiVLFDV KD\ TXH VXVWLWXLU HO FDEOH GH
alimentación eléctrica.
$7(1d21RFDVRGHFRQH[}HVWULIiVLFDVVHPQHXWURRXPRQRIiVLFRRFDERGHDOLPHQWDomRHOpFWULFDWHPGH
ser substituído.
Collegamento Trifase - Three-phase connection - Branchement triphasé
'UHLSKDVLJ$QVFKOXVV&RQH[LyQWULIiVLFD&RQH[mRWULIiVLFR
Blocco terminazione
Terminal block
Bloc d’achèvement
Einheit zum Kabelanschluss
%ORTXHWHUPLQDFLyQ
Grupo de terminação
Blocco terminazione
Terminal block
Bloc d’achèvement
Einheit zum Kabelanschluss
%ORTXHWHUPLQDFLyQ
Grupo de terminação
&DYR&DEOH&kEOH
Kabel - Cable - Cabo
Morsettiera
Terminal strip
%RvWHjERUQHV
Klemmleiste
Bornera
Quadro de bornes
Sezioni nominali dei cavi da utilizzare:
Nominal sections of cables to use:
6HFWLRQVQRPLQDOHVGHVFkEOHVjXWLOLVHU
Nominaler Leiterquerschnitt:
Secciones nominales de los cables que hay que utilizar:
Secções nominais dos cabos a utilizar:
380-415V3N
min. H05VV-F o H05RN-F - 5 x 1,5mm
2
220-240V3
min. H05VV-F o H05RN-F - 4 x 2,5mm
2
220-240V
min. H05VV-F o H05RN-F - 3 x 4mm
2
Collegamento trifase - Three-phase connection
Raccordement triphasé - Dreiphasig Anschluß
Conexión trifásica - Ligação trifásica
T
Grigio - Grey - Gris - Grau - Gris - Cinza
S
Nero - Black - Noir - Schwarz - Negro - Preto
R
Marrone - Brown - Brun - Braun - Maròn - Marron
N
Azzurro - Blue - Bleu - Blau - Azùl - Azul
Collegamento monofase - Single phase connection
Raccordement monophase - Einphasigem Anschluß
Conexión monofásica - Ligação mono-fásica
Colore cavi - Wires colour - Couleur cables - Farbe der Drähte - Color cables - Cor cabos
N
Bianco - White - Blanc
Weiß - Blanco - Branco
T
Nero - Black - Noir
Schwarz - Negro - Preto
1
N
Azzurro - Blue - Bleu
Blau - Azùl - Azul
T
Marrone - Brown - Marron
Braun - Maròn - Marron
2
X
Содержание TEOREMA A
Страница 1: ......
Страница 5: ...III TEOREMA A 25 2 8 17 20 10 1 91 9 21 11 14 6 12 13 24 29 30 31 27 26 34 OK 23 35...
Страница 36: ...Italiano Italiano 28 IT...
Страница 64: ...English English 28 EN...
Страница 92: ...Fran ais Fran ais 28 FR...
Страница 120: ...Deutsch Deutsch 28 DE...
Страница 148: ...Espa ol Espa ol 28 ES...
Страница 176: ...Portug es Portug es 28 PT...
Страница 184: ...XIV...
Страница 185: ......
Страница 186: ......
Страница 187: ......
Страница 188: ......
Страница 189: ......
Страница 190: ......
Страница 192: ...58332 0 6S 1 6 2 0 12 7 57 15...