General description:
The electronic control panel Elpro 70/3 Plus, new generation, is designed to operate the sliding gate operators MEC 200. Power supply is 230-380V
single- and three-phase. It is built in full compliance with the Low Voltage and Electro-Magnetic Compatibility Regulations. Fitting operations are recommended to be carried
out by a qualified technician in conformity to the existing safety standards. The manufacturing company declines any responsability for incorrect handling and applications;
also, it reserves the right to change or update the control panel any time.
Failure to follow installation regalations may result in serious damage to property and persons.
PLEASE NOTE:
- The control panel is fitted inside Mec 200.
- Make sure that the power supply to the electronic programmer is 230V
±
10%
- Make sure that the power supply to the Electric Motor is 230V
±
10%
- For distances of over 50 metres we recommend using electric cables with bigger sections.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5 mm
2
section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50 m.Use 1 mm
2
section wires for
limit switches, photocells, push-buttons/key-switch and accessories.
- Bridge terminals 11 and 12 if no photocells are required.
- Bridge terminals 5 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
Dip-Switch:
1= ON Photocells.Stop on opening
2= ON Radio. No reverse on opening
3= ON Automatic closing
4= ON Preflashing activated
5= ON Radio.Step by step. stop in between
6= ON Dead Man Control (Dip 4=OFF n Dip 3=OFF)
7= ON No light during dwell time
8= OFF. No function
PLUS
70/3
GB
SINGLE-/THREE-PHASE FOR SLIDING GATE OPERATORS MEC 200
DIP-SWITCH
1
4 5 6 7 8
2
ON
OFF
3
In case of failure of the panel:
- Make sure that the power supply to the electronic programmer is 230V
±
10% or 400V
±
10%
- Make sure that the power supply to the Electric Motor is 230V
±
10% or 400 V
±
10%
- Check fuses
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the control panel to the electric motor
Drwg. No.
4138
DIP-SWITCH
ON
OFF
1
4 5 6 7 8
2 3
L2
L3
L4
L5
L6
L7
400V
F1=8A Mains
F2=8A Mains
F3=8A Mains
F5=1A Flashing
Lamp Protection
F4=630mA
Transformer
Protection
F6=630mA for 24V
protection
TRANSFORMER
MOTOR RUN TIME
from 5 to 150s
DWELL TIME
from 5 to 150s
PEDESTRIAN TIME
from 3 to 30s
-
+
-
+
-
+
T3
T2
T1
T
NEUTRAL
S
LIVE
MOTOR
M
U
W
V
16
μ
F CAPACITOR for
single-phase application
1
4
10
2
5
3
9
24V RADIO POWER
SUPPLY
INDICATION LAMP CLOSE
COMMON
7
8
6
STOP
CLOSE
OPEN
RADIO CONTACT
FLASHING LAMP
230V 25W max
19
18
16 17
23
22
11 12
PHOTOCELL CONTACT
13
15
14
LIMIT SWITCH CLOSE
LIMIT SWITCH OPEN
COMMON
24V PHOTOCELL
SUPPLY
20 21
SAFETY SWITCH
25
26
24
29
28
27
230V
±
10% 50Hz
SINGLE-PHASE
POWER SUPPLY
L9
L8
L1
L10
R
LIVE
230/400V
±
10% 50Hz
THREE-PHASE POWER
SUPPLY
INDICATION
LIGHT
24V max 3W
230V
COM.
+24
ELECTRIC LOCK
OR 12V AC RELAY FOR 230V
COURTESY LIGHT
-
+
T4
EXT TIME (Electric lock &
Courtesy Light) from 2 to 255s
INDICATION LAMP OPEN
RADIO
PLUG-IN
CARD CONNECTOR
PIC. 8