OPERATING MODES
10
22 23
230V MAX 25W
230V
400V
Dwell Time
from 5 to 128s
T2
-
+
-
+
-
+
27
22
R
T
S
LIVE
29
28
230V
±
10% 50Hz
SINGLE-PHASE
NEUTRAL
LIVE
400V
±
10% 50Hz THREE-PHASE
230/400V
±
10% 50Hz
THREE-PHASE MOTOR
M 3
U
W
V
25
26
24
230V
±
10% 50Hz
SINGLE-PHASE
MOTOR
M 2
U
W
V
25
26
24
16
μ
F CAPACITOR
Drwg. No.
4138
Led Status Indication:
L1 = 230V 50Hz power supply. Alight
L2 = Photocells, if obstructed light goes off
L3 = Open. Alight whenever an Open pulse is given
L4 = Close. Alight whenever a Close pulse is given
L5 = Stop. It goes off on pulsing Stop
L6 = Radio. It goes on by pressing a transmitter button
L7 = Gate Status; it flashes on gate opening
L8 = Limit switch Close; off when gate is closed
L9 = Limit switch Open; off when gate is open
L10 = It stays on for a time equal to the time set on T4
SINGLE-/THREE-PHASE FOR SLIDING GATE OPERATORS MEC 200
PLUS
70/3
GB
Single- (230V) and
Three-phase (400V) Motors:
MOTOR RUN TIME
OPEN / CLOSE
from 5 to 150s
Flashing lamp:
4
7
DIP-SWITCH 4 and 7:
ON: Pre-flashing
OFF: No pre-flashing
ON: Lamp is not operating during
Dwell Time. Automatic Mode.
OFF: It flashes during Dwell Time .
Automatic Mode.
Power supply:
FADINI
l'apricancello
DWELL TIME
from 5 to 150s
Hold on switched (Deadman) control:
DIP-SWITCH 6
6
ON= Deadman Control. Dip-switch 4=OFF
and Dip-switch 3=OFF
OFF= Standard Operations
3
DIP-SWITCH 3
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
closing by pulse
Automatic / Semiautomatic:
Pedestrian Opening:
Trimmer T3 from 3 to 30s.
It can be activated by any pulse (eg. by remote control) superior to 2s
COMMON
ELECTRICAL POWER CONNECTIONS
-
+
Trimmer
T3