ELECTRONIC CONTROL CARD
ELPRO 70/3 PLUS
VOLTAGE CUT OFF
MICROSWITCH
LIMIT SWITCH
TERMINAL BOARD
TO BE CONNECTED
TO THE MAIN PANEL
VOLTAGE CUT OFF
SAFETY
DEVICE
MAIN BOARD
CONTROL PANEL
ELPRO 10 PLUS
LIMIT SWITCH
MICROSWITCH
COMMON
LIVE 2
LIVE 1
LIVE 1
COMMON
LIVE 2
VOLTAGE CUT OFF
MICROSWITCH
MAIN BOARD
CONTROL PANEL
ELPRO 70/3 PLUS N.C.
LIVE 1
COMMON
LIVE 2
- It is recommended to fit
three-phase
operators with
a safety device
consisting of a switch to cut off power to the low voltage circuit.
Connections are
in series with the limit switch common terminal
(pic. 9). The switch is activated whenever the override spanner is
inserted for manual operations or the operator cover is removed.
Should the limit switches be wrongly connected so that their action opposes the normal travelling of the gate, reverse their connections
in the main board. Change over the live connections, keep the
common fixed
in the same terminal.
PIC. 9
ILLUMINATED LED
BOARD ON VOLTAGE