Power output
Supply voltage
Frequency
Absorbed power
Absorbed current
Motor rotation speed
Capacitor
Intermittent service

ELECTRIC MOTOR

SINGLE-PHASE

THREE-PHASE

SINGLE-PHASE

THREE-PHASE

THREE-PHASE

 MEC 200 GEAR BOX

Rated torque
Gear ratio
Running speed
Oil temperature
Oil type (AGIP ROTRA THT)
Protection standard
Weight. Mec 200 Vertical
Weight. Mec 200 Horizontal
Max. gate weight

Duty cycle

25 s Open - 30 s Dwell - 25 s Close

Time for one complete cycle 80 s

No. of complete cycles Open-Dwell-Close: 45/Hour

No. of complete cycles per year (8 hours’ service per day): 131˙000 cycles

Power supply
Voltage output
Low voltage output
E.M. max. power output
Line fuses
Secondary fuses
Logic switching
Box dimensions
Protection standard
Elesta relay marking

ELPRO 10 PLUS ELECTRONIC PANEL

Power transformer
Magnetic core
Voltage
Outputs
Frequency
Insulation
Main switch
Contact rating

230 / 400 V

230 V - 25 W

24 V - 10 W

1˙100 W

5 A

1A - 630 mA

Open-Stop-Close

290x205x140

IP 437

VDE-CSA-DEMCO-SEV

10 A 230 V

4 A 400 V

20 VA

1.5 W / 0.5 thick

0-230 V

0-12-18-24 V

50-60 Hz

4 Kv x 1’

T215K Mark SAA

15A 250 V AC

0.37 KW (0.5 HP)

230 V

50/60 Hz

510 W

2.4 A

1˙380 rpm

20 

μ

F

S3

0.37 KW (0.5 HP)

230/400 V

50/60 Hz

575 W

2.1-1.2 A

1˙380 rpm

S3

0.73 KW (1 HP)

230 V

50/60 Hz

1˙130W

5.7 A

1˙380 rpm

30 

μ

F

S3

0.73 KW (1 HP)

230/400 V

50/60 Hz

1˙030 W

3.7-2.2 A

1˙380 rpm

S3

1.1 KW (1.5 HP)

230/400 V

50/60 Hz

1˙500 W

5.1-3 A

1˙380 rpm

S3

40 Nm

1:32

9.6 m/1’

-20

°

C +80

°

C

W 80 - Kg 0.22

IP 557

19 Kg

19.5 Kg

400 Kg

40 Nm

1:32

9.6 m/1’

-20

°

C +80

°

C

W 80 - Kg 0.22

IP 557

18 Kg

18.5 Kg

450 Kg

80 Nm

1:32

9.6 m/1’

-20

°

C +80

°

C

W 80 - Kg 0.22

IP 557

23 Kg

23.5 Kg

800 Kg

80 Nm

1:32

9.6 m/1’

-20

°

C +80

°

C

W 80 - Kg 0.22

IP 557

21 Kg

21.5 Kg

850 Kg

110 Nm

1:32

9.6 m/1’

-20

°

C +80

°

C

W 80 - Kg 0.22

IP 557

25 Kg

25.5 Kg

1˙200 Kg

TECHNICAL SPECIFICATIONS

SECTION VIEW WITH BRAKE (on request) AND RELEASE KEY

BUILT-IN AIR-COOLED BRAKE
(on request)

ADJUSTMENT

SPANNER E17

ANTI-CLOCKWISE

TO RELEASE

PIC. 12

Drwg. No. 3404

Содержание MEC 200

Страница 1: ...Electro mechanical sliding gate operator Vertical and horizontal installation Gear movements and worm gear coupling in oil bath fully mounted on ball bearings GB Installation manual MEC 200...

Страница 2: ...t into an unbalanced travelling of the gate IMPORTANT Make sure that gate stops are fixed in the open and closed gate positions so that the gate does not over travel the permitted limit and go out of...

Страница 3: ...lease spanner E17 supplied with the equipment the gate can be freely moved by hand Temporary clamp the rack to the gate so that it can adequately mesh the driving gear the rack must mesh the driving g...

Страница 4: ...se items Pic 6 The safety pneumatic edge is to be fitted to the gate edge and is connected to the control box by a cable to be automatically rewound to take up the slack A remote controlled switch can...

Страница 5: ...tton switches are required N W To fit extra accessories such as lights CCTV etc use only solid state relays to prevent damages to the microprocessor DIP SWITCH 1 4 5 6 7 8 2 ON OFF 3 Dip Switch 1 ON P...

Страница 6: ...opening reverse it on closing in case of an obstacle Button switch 3 4 5 6 STOP COMMON OPEN CLOSE Limit switch 10 COMMON 8 9 LIMIT SWITCH CLOSE LIMIT SWITCH OPEN Radio Contact 7 3 COMMON RADIO CONTACT...

Страница 7: ...Automatic Closing OFF No Automatic Semi automatic closing by pulse Automatic Semiautomatic Automatic Operation any pulse opens the gate the gate stays open as long as the Dwell time expires as set by...

Страница 8: ...r Dip Switch 1 ON Photocells Stop on opening 2 ON Radio No reverse on opening 3 ON Automatic closing 4 ON Preflashing activated 5 ON Radio Step by step stop in between 6 ON Dead Man Control Dip 4 OFF...

Страница 9: ...pulsing Step by step 2 5 ON Step by step Stop in between OFF Standard operating mode ON Gate is not reversed while opening OFF Any pulse reverses the gate DIP SWITCH 2 and 5 NEVER set BOTH of them to...

Страница 10: ...switch Open off when gate is open L10 It stays on for a time equal to the time set on T4 SINGLE THREE PHASE FOR SLIDING GATE OPERATORS MEC 200 PLUS 70 3 GB Single 230V and Three phase 400V Motors MOT...

Страница 11: ...ommended to fit three phase operators with a safety device consisting of a switch to cut off power to the low voltage circuit Connections are in series with the limit switch common terminal pic 9 The...

Страница 12: ...ntrol The system is in an oil bath and can be adjusted to the gate weight Adjusting is by a screw which is located on one side of the operator pic 11 A special spanner E17 is provided with the equipme...

Страница 13: ...ating 230 400 V 230 V 25 W 24 V 10 W 1 100 W 5 A 1A 630 mA Open Stop Close 290x205x140 IP 437 VDE CSA DEMCO SEV 10 A 230 V 4 A 400 V 20 VA 1 5 W 0 5 thick 0 230 V 0 12 18 24 V 50 60 Hz 4 Kv x 1 T215K...

Страница 14: ...14 MEC 200 OVERALL DIMENSIONS 467 245 174 130 290 60 38 498 1 000 160 130 290 92 467 172 92 280 260 120 200 PIC 13 MEC 200 VERTICAL MEC 200 HORIZONTAL FIXING BASE PLATE 1 meter LENGHTS GEAR RACK...

Страница 15: ...T STEEL GEAR RACK 22 x 22 mm THICKNESS STEEL GEAR RACK WITH FIXING SLOTS NYLON GEAR RACK 8 mm THICKNESS POWER CUT OFF DEVICE E 17 RELEASE SPANNER FIXING BASE PLATE LIMIT SWITCH STRIKING PLATES FOR SCR...

Страница 16: ...knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of improvement EUROPEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL REQUIREMENTS OF TH...