background image

7

PLUS

10

GB

SINGLE- AND THREE-PHASE FOR SLIDING GATES
AND AUTOMATIONS FITTED WITH LIMIT SWITCHES

Single- (230V) and Three-phase (400V) Motors:

-

+

T1

MOTOR RUN TIME

OPEN / CLOSE
from 5 to 128s

T2

-

+

CAPACITOR

18

16

17

COMMON

M

MOTOR

U

W

V

Flashing lamp:

19 20

 230V MAX 25W

4

7

DIP-SWITCH 4 and 7:

ON: Pre-flashing

OFF: No pre-flashing

ON: Lamp is not operating during

Dwell Time. Automatic Mode.

OFF: It flashes during Dwell Time .

Automatic Mode.

230V

400V

Power supply:

Hold on switched (Deadman) control:

Open and Close operations are achieved "by holding a switch on"
(no relay self-holding is involved) therefore a phisical attendance
is required to keep the gate opening or closing until either the
button or key is released.

DIP-SWITCH 6

6

ON= Deadman Control. Dip-switch 4=OFF

and Dip-switch 3=OFF

OFF= Standard Operations

Remote Controlled Operations Excluded during Dwell Time on Automatic Mode:

3

ON= Automatic Closing

OFF= Closing by Pulse

5

ON: Step by step. Stop in between

OFF: Standard Operations

With this setting it is not possible to operate the gate by remote control during the dwell time on automatic mode.
DIP-SWITCH 2=ON, 3=ON and 5=ON

2

ON: No reversing on opening

OFF: Travel reversing on any pulsing

3

DIP-SWITCH 3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic
          closing by pulse

Automatic / Semiautomatic:

Automatic Operation: 

any pulse opens the gate, the gate stays open as long as the Dwell time

expires as set by T2 trimmer, then it closes automatically, no pulsing is required.

Semi-automatic Operation: 

any pulse opens the gate that stays open. A second pulse to Close is

required for the gate to close.

Dwell Time

from 5 to 128s

T2

-

+

Pedestrian Opening:

-

+

Trimmer T3 at minimum disactivates Pedestrian Opening
from 3 to 30s. It can be activated by any pulse (eg. by remote control) superior to 2s

How it works: Set the clock to the required time. On the pre-set time the gate is automatically opened and held open. Any further
pulsing (even by remote control) is not accepted by the system until the time pre-set by the clock has expired. On expiring and
after the pre-set dwell time the gate is closed automatically.
T3 trimmer on to zero, Dip-Switch 3=ON.

Time clock installation:

DIP-SWITCH No.3=ON Automatic Closing

3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic

closing by pulse

-

+

Pedestrian Trimmer 

T3

set on to zero

4

3

COMMON

COMMON

OPEN

NO

External Time Clock

FADINI

l'apricancello

T3

PEDESTRIAN TIME

from 3 to 30s

230V 

±

10% 50Hz

SINGLE-PHASE

21

22

NEUTRAL

S

LIVE

23

22

R

21

22

T

R

S

LIVE

23

22

400V 

±

10% 50Hz

THREE-PHASE

LIVE

NEUTRAL

DWELL TIME

from 5 to 128s

Drwg. No.

4135

ELECTRICAL POWER CONNECTIONS

OPERATING MODES

Содержание MEC 200

Страница 1: ...Electro mechanical sliding gate operator Vertical and horizontal installation Gear movements and worm gear coupling in oil bath fully mounted on ball bearings GB Installation manual MEC 200...

Страница 2: ...t into an unbalanced travelling of the gate IMPORTANT Make sure that gate stops are fixed in the open and closed gate positions so that the gate does not over travel the permitted limit and go out of...

Страница 3: ...lease spanner E17 supplied with the equipment the gate can be freely moved by hand Temporary clamp the rack to the gate so that it can adequately mesh the driving gear the rack must mesh the driving g...

Страница 4: ...se items Pic 6 The safety pneumatic edge is to be fitted to the gate edge and is connected to the control box by a cable to be automatically rewound to take up the slack A remote controlled switch can...

Страница 5: ...tton switches are required N W To fit extra accessories such as lights CCTV etc use only solid state relays to prevent damages to the microprocessor DIP SWITCH 1 4 5 6 7 8 2 ON OFF 3 Dip Switch 1 ON P...

Страница 6: ...opening reverse it on closing in case of an obstacle Button switch 3 4 5 6 STOP COMMON OPEN CLOSE Limit switch 10 COMMON 8 9 LIMIT SWITCH CLOSE LIMIT SWITCH OPEN Radio Contact 7 3 COMMON RADIO CONTACT...

Страница 7: ...Automatic Closing OFF No Automatic Semi automatic closing by pulse Automatic Semiautomatic Automatic Operation any pulse opens the gate the gate stays open as long as the Dwell time expires as set by...

Страница 8: ...r Dip Switch 1 ON Photocells Stop on opening 2 ON Radio No reverse on opening 3 ON Automatic closing 4 ON Preflashing activated 5 ON Radio Step by step stop in between 6 ON Dead Man Control Dip 4 OFF...

Страница 9: ...pulsing Step by step 2 5 ON Step by step Stop in between OFF Standard operating mode ON Gate is not reversed while opening OFF Any pulse reverses the gate DIP SWITCH 2 and 5 NEVER set BOTH of them to...

Страница 10: ...switch Open off when gate is open L10 It stays on for a time equal to the time set on T4 SINGLE THREE PHASE FOR SLIDING GATE OPERATORS MEC 200 PLUS 70 3 GB Single 230V and Three phase 400V Motors MOT...

Страница 11: ...ommended to fit three phase operators with a safety device consisting of a switch to cut off power to the low voltage circuit Connections are in series with the limit switch common terminal pic 9 The...

Страница 12: ...ntrol The system is in an oil bath and can be adjusted to the gate weight Adjusting is by a screw which is located on one side of the operator pic 11 A special spanner E17 is provided with the equipme...

Страница 13: ...ating 230 400 V 230 V 25 W 24 V 10 W 1 100 W 5 A 1A 630 mA Open Stop Close 290x205x140 IP 437 VDE CSA DEMCO SEV 10 A 230 V 4 A 400 V 20 VA 1 5 W 0 5 thick 0 230 V 0 12 18 24 V 50 60 Hz 4 Kv x 1 T215K...

Страница 14: ...14 MEC 200 OVERALL DIMENSIONS 467 245 174 130 290 60 38 498 1 000 160 130 290 92 467 172 92 280 260 120 200 PIC 13 MEC 200 VERTICAL MEC 200 HORIZONTAL FIXING BASE PLATE 1 meter LENGHTS GEAR RACK...

Страница 15: ...T STEEL GEAR RACK 22 x 22 mm THICKNESS STEEL GEAR RACK WITH FIXING SLOTS NYLON GEAR RACK 8 mm THICKNESS POWER CUT OFF DEVICE E 17 RELEASE SPANNER FIXING BASE PLATE LIMIT SWITCH STRIKING PLATES FOR SCR...

Страница 16: ...knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of improvement EUROPEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL REQUIREMENTS OF TH...

Отзывы: