background image

5.       DESCRIPTION OF THE KEYS

The functions of the FAACTOTUM keys are follows:

1

6

2

7

3

8

4

9

5

0

CLEAR

ENTER

A

K

U

C

M

W

E

O

Y

G

Q

I

S

ON-OFF

PG

PG

ESC

?

TOTUM

F1

F2

F3

F4

F5

*

/

-

+

.

SHIFT

B

D

F

H

J

L

N

P

R

T

V

X

Z

1

2

2

3

4

5

6

6

4

7

8

9

Fig.  6

4

ARROW RIGHT/LEFT

Press the arrow keys to move sideways in a menu to select
the desired option.
Once selected, press ENTER to confirm.

5

CLEAR

CLEAR

This key cancels the data item which has been entered and
is shown on the display but has not yet been confirmed by
pressing the ENTER key.

6

1

6

F1

*

A

C

B

D

ALPHANUMERIC KEYS

The alphanumeric keys are used for
entering data into the data entry
fields in the menus and to activate
the functions F1...F5

(

the only function key currently enabled is F1=space

)

.

Each key is divided into two parts: one part has a white
background, the other a grey background. The normal
function of the key is shown by the character on the white
background.
When pressed together with the SHIFT key (see point 8) the
key has the function shown by the character on the grey
background.

9

?

HELP

When enabled, this key provides useful information regarding
programming.

8

SHIFT

SHIFT

Press this key to activate the alternative function of keys
which have a double function (e.g. alphanumeric keys).
Press and hold before pressing the key with the double
function.

7

ESC

ESC

Press this key to return to the initial menu for the subject for
which programming is being performed.

3

3

ENTER

ENTER

Press this key to confirm the selected option or data item
and make it active, and to go to the subsequent menu.
Before pressing ENTER the data item is shown on the display
but is not saved in the memory.   So if for example you return
to the previous menu the data item will be lost.

1

ON-OFF

ON/OFF

Press this key to turn the FAACTOTUM on and off.
Warning: if the programmer is turned off before the
configuration currently being set has been saved in the
memory or it has been transferred to the 460P card memory,
all the program data entered will be lost.

2

PG

PG

ARROW UP/DOWN
PAGE UP/PAGE DOWN

Press the arrow keys to move up and down within
a menu to select the desired option. Press together
with the SHIFT key (see point 8) to move back-
ward or forward by several menus (where ena-
bled).
They are also used in the time learning and motor
test cycle.

Содержание FAACTOTUM

Страница 1: ...FAACTOTUM FAACTOTUM R...

Страница 2: ......

Страница 3: ...ms or it can be modified Besides programming the FAACTOTUM can be used to perform diagnostics and to check the operation of the automation and the connection to an external PC appropriate software pro...

Страница 4: ...rol unit 460P The FAACTOTUMcanbeconnectedtothepowerpackwiththe batteries fitted since the external power source is used preferentiallytosavebatterycharge The internal batteries operate as a buffer sup...

Страница 5: ...LP When enabled this key provides useful information regarding programming 8 SHIFT SHIFT Press this key to activate the alternative function of keys which have a double function e g alphanumeric keys...

Страница 6: ...his function prevents the FAACTOTUM from being used by anyone who does not know the password but it does not prevent access to the configuration saved on the 460P card Select the mode by moving the ar...

Страница 7: ...cter alphanumeric identification If you know the number enter it the corresponding identification will appear and press ENTER Alternatively pressing the and keys displays all the memory locations one...

Страница 8: ...uses a short closure movement before the leaves open to facilitateoperationoftheclosedpositionelectriclocks Selectoption 1 Inversion stroke enabled 2 Inversion stroke disabled 1 F1 2 F2 or ENTER Make...

Страница 9: ...through the logics avail able and their identifications When the desired logic appears press ENTER to select it If you know the location key in the number the identification appears and press ENTER o...

Страница 10: ...rrow on the display moves to select the effect of the subsequent pulse Close Leaf 2 completely and press ENTER cont ASSOCIATE CHOSEN FUNCTION WITH INPUT AND PRESS ENTER INP 2 XXXXXX ENTER INPUT MODULE...

Страница 11: ...eviously been set When the key is pressed Leaf 2 begins to close and the arrow on the display moves alongside the DECELERATION option When Leaf 2 has reached the position where you wish closing decele...

Страница 12: ...s for entering the register value DEC to enter the register value in decimal BIN to enter the register value in binary If DEC is selected enter the value using the number keys If BIN is selected press...

Страница 13: ...After entering the identification press ENTER to save and proceed If you select an occupied location saving will cause the resident configuration to be overwritten A K U C M W E O Y G Q I S B D F H J...

Страница 14: ...omplete diagnostics on the automation the FAACTOTUM must be connected to the 460P electronic control unit Press ENTER to continue ENTER The menus contained in the diagnostics with the exception of the...

Страница 15: ...IMPULSE COMMAND 1 OPEN A 2 OPEN B 3 STOP 4 CLOSE ESC TO EXIT From the time of its installation the 460P counts the number of cycles performed by the automation to give an idea of its degree of usage...

Страница 16: ...nfiguration on the card it can be loaded from this menu Select option 1 Load 460P standard configuration resident in the FAACTOTUM 2 Ignore the question and proceed 1 F1 2 F2 SELECT MODE 14 1 F1 2 F2...

Страница 17: ...time as the Gatecoder and vice versa 5 With the sole exception given below it is not possible to assign the same function to more than one terminal 6 The 460P card terminal IN2 can also be configured...

Страница 18: ...XXXXXX 60Hzmainspowersupply 30 XXXXXXX0 FAILSAFEoninputFSW CLdisabled disabled XXXXXXX1 FAILSAFEoninputFSW CLenabled XXXXXX0X FAILSAFEoninputFSW OPdisabled disabled XXXXXX1X FAILSAFEoninputFSW OPenabl...

Страница 19: ...mand The contact remains closed until the state is reset REG No VALUE FUNCTION DEFAULT 14 1001XXXX panicstateactivated 0000XXXX Default standardwarninglightfunction 3 Automation open state contact The...

Страница 20: ...ds 14 11 ELECTRIC LOCK ACTIVATION TIME Sets the duration of electric lock activation Thesetvaluemustbelowerthantheopeningandclosingleaf delay times REG No VALUE FUNCTION DEFAULT 56 seconds electric lo...

Страница 21: ......

Страница 22: ......

Отзывы: