USE GATECODER ?
1 YES
2 ->NO
2
F2
1
F1
USE LIMIT SWITCHES?
1->YES
2 NO
SLOW DOWN LEAVES?
1->YES
2 NO
1
F1
2
F2
ELECTRIC LOCK?
1 YES
2->NO
CLOSING?
1-> ONE 2 TWO 3 NO
1
F1
3
F3
8.1
ELECTRIC LOCKS
2
F2
REVERSING STROKE?
1-> YES
2 NO
1
F1
2
F2
1
F1
2
F2
OPENING ELECTRIC LOCK?
1-> YES
2 NO
go to
“8.2 LOGIC SELECTION”
B
à
1
F1
2
F2
1
F1
2
F2
6
(cont.)
(cont.)
Use of limit switches on automation:
1 = Limit switches used
2 = Limit switches not used
1
F1
2
F2
or
ENTER
+
Make the selection by moving the arrow-shaped cursor alongside the desired option
using the
ï
and
ð
keys and pressing ENTER, or key in the corresponding number
directly.
Deceleration is performed by using the GATECODER, using the limit switches or by
time, depending on the choices made. Choose whether to use the leaf deceleration
function:
1 = Use leaf deceleration function
2 = Do not use leaf deceleration function
1
F1
2
F2
or
ENTER
+
Make the selection by moving the arrow-shaped cursor alongside the desired option
using the
ï
and
ð
keys and pressing ENTER, or key in the corresponding number
directly.
Select option:
1 = Electric lock(s) used
2 = Electric lock(s) not used - go to logic selection.
1
F1
2
F2
or
ENTER
+
Make the selection by moving the arrow-shaped cursor alongside the desired
option using the
ï
and
ð
keys and pressing ENTER, or key in the corresponding
number directly.
The inversion stroke causes a short closure movement before the leaves open to
facilitate operation of the closed position electric locks.
Select option:
1 = Inversion stroke enabled
2 = Inversion stroke disabled
1
F1
2
F2
or
ENTER
+
Make the selection by moving the arrow-shaped cursor alongside the desired
option using the
ï
and
ð
keys and pressing ENTER, or key in the corresponding
number directly.
Use of electric locks on the system to lock the gate in an open position:
1 = Open position electric locks present
2 = Open position electric locks not present - go to logic selection.
1
F1
2
F2
or
ENTER
+
Make the selection by moving the arrow-shaped cursor alongside the desired
option using the
ï
and
ð
keys and pressing ENTER, or key in the corresponding
number directly.
Using the GATECODER on the automation:
1 = Use GATECODER
2 = Do not use GATECODER
Make the selection by moving the arrow-shaped cursor alongside the desired option
using the
ï
and
ð
keys and pressing ENTER, or key in the corresponding number
directly.
1
F1
2
F2
or
ENTER
+
Enter the number of electric locks in the automation which lock the gate in a closed
position:
1 = 1 closed position electric lock (electric lock on leaf 1)
2 = 2 closed position electric locks (electric locks on leaf 1 and leaf 2)
3 = no closed position electric lock
➲
Option 2 appears only if “NUMBER OF OPERATORS = 2” has been set.
1
F1
2
F2
or
ENTER
+
Make the selection by moving the arrow-shaped cursor alongside the desired option
using the
ï
and
ð
keys and pressing ENTER, or key in the corresponding number
directly.
go to
“8.2 LOGIC SELECTION”
B
à