background image

Select the source from which you wish to load the program:
1 = From 460P if you wish to work on the program already present on the card
2 = From the memory if you wish to work on a program previously saved in the
FAACTOTUM memory
Make the choice by moving the arrow-shaped cursor alongside the desired
option using the 

ò

 and 

ñ

 keys and pressing ENTER, or key in the corresponding

number directly.

1

F1

2

F2

or

PG

PG

ENTER

+

8.

PROGRAMMING

LOAD

PROGRAM

 1->FROM 460P
 2   FROM MEMORY

2

F2

1

F1

 CONNECT TO 460 P

AND PRESS ENTER

SELECT MEMORY WITH

ñ

 AND 

ò

THEN PRESS ENTER
MEMORY : 1 xxxxxxxx

ENTER

ENTER

DO YOU WANT TO

1-> CHANGE
2

TRANSFER

1

F1

2

F2

ENTER

CONNECT TO 460 P

AND PRESS ENTER

ENTER

PROGRAMMING

         XXXXXXXX

PRESS ENTER TO CONT.

1

F1

2

F2

NUMBER OF OPERATORS?

  1->ONE

 2  TWO

A

go to 

“8.7 TRANSFERRING THE PROGRAM TO THE CARD”

à

E

(cont.)

To load the program from the 460P, the FAACTOTUM must be connected to it
using the appropriate cable.
- If the FAACTOTUM is already connected, press ENTER
- If the FAACTOTUM is disconnected, connect it and press ENTER
If you press ENTER with the FAACTOTUM disconnected, an error message ap-
pears.
In this case press ENTER to return to this menu.

ENTER

To load the program from the FAACTOTUM’s internal memory, it must be selected
from those available.
Each program in the memory is represented by a number (01 to 16 indicating its
memory location) and an 8-character alphanumeric identification. If you know
the number, enter it (the corresponding identification will appear) and press ENTER.
Alternatively, pressing the 

ò

 and 

ñ

 keys displays all the memory locations one at

a time along with the resident program identifications. To select the desired pro-
gram, press ENTER when its identification is shown.

or

1

6

2

7

3

8

4

9

5

0

F1

F2

F3

F4

F5

*

/

-

+

.

PG

PG

ENTER

+

Once the program resident in the FAACTOTUM memory has been selected, it is
possible to:
1 = Modify it then save in memory
2 = Transfer it directly to the 460P
Make the selection by moving the arrow-shaped cursor alongside the desired
option using the     and 

ò

 keys and pressing ENTER, or directly enter the number

corresponding to the desired function.

ò

1

F1

2

F2

or

PG

PG

ENTER

+

To transfer the program to the 460P the FAACTOTUM must be connected to it using
the appropriate cable.
- If the FAACTOTUM is already connected, press ENTER.
- If the FAACTOTUM is disconnected, connect it and press ENTER.
The subsequent menus allow the program to be transferred.
If you press ENTER with the FAACTOTUM disconnected, an error message appears.

ENTER

ENTER

The identification of the program loaded from the 460P is displayed.
If                            appears, this means that the 460P standard configuration has
been loaded.
Press ENTER to proceed.

òò

ò

ò

ò

ò

ò

5

Number of operators present in the automation:
1 = Single leaf (1 operator)
2 = Double leaf (2 operators)

Make the selection by moving the arrow-shaped cursor alongside the desired
option using the 

ï

 and 

ð

 keys and pressing ENTER, or key in the corresponding

number directly.

1

F1

2

F2

or

ENTER

+

ò

Содержание FAACTOTUM

Страница 1: ...FAACTOTUM FAACTOTUM R...

Страница 2: ......

Страница 3: ...ms or it can be modified Besides programming the FAACTOTUM can be used to perform diagnostics and to check the operation of the automation and the connection to an external PC appropriate software pro...

Страница 4: ...rol unit 460P The FAACTOTUMcanbeconnectedtothepowerpackwiththe batteries fitted since the external power source is used preferentiallytosavebatterycharge The internal batteries operate as a buffer sup...

Страница 5: ...LP When enabled this key provides useful information regarding programming 8 SHIFT SHIFT Press this key to activate the alternative function of keys which have a double function e g alphanumeric keys...

Страница 6: ...his function prevents the FAACTOTUM from being used by anyone who does not know the password but it does not prevent access to the configuration saved on the 460P card Select the mode by moving the ar...

Страница 7: ...cter alphanumeric identification If you know the number enter it the corresponding identification will appear and press ENTER Alternatively pressing the and keys displays all the memory locations one...

Страница 8: ...uses a short closure movement before the leaves open to facilitateoperationoftheclosedpositionelectriclocks Selectoption 1 Inversion stroke enabled 2 Inversion stroke disabled 1 F1 2 F2 or ENTER Make...

Страница 9: ...through the logics avail able and their identifications When the desired logic appears press ENTER to select it If you know the location key in the number the identification appears and press ENTER o...

Страница 10: ...rrow on the display moves to select the effect of the subsequent pulse Close Leaf 2 completely and press ENTER cont ASSOCIATE CHOSEN FUNCTION WITH INPUT AND PRESS ENTER INP 2 XXXXXX ENTER INPUT MODULE...

Страница 11: ...eviously been set When the key is pressed Leaf 2 begins to close and the arrow on the display moves alongside the DECELERATION option When Leaf 2 has reached the position where you wish closing decele...

Страница 12: ...s for entering the register value DEC to enter the register value in decimal BIN to enter the register value in binary If DEC is selected enter the value using the number keys If BIN is selected press...

Страница 13: ...After entering the identification press ENTER to save and proceed If you select an occupied location saving will cause the resident configuration to be overwritten A K U C M W E O Y G Q I S B D F H J...

Страница 14: ...omplete diagnostics on the automation the FAACTOTUM must be connected to the 460P electronic control unit Press ENTER to continue ENTER The menus contained in the diagnostics with the exception of the...

Страница 15: ...IMPULSE COMMAND 1 OPEN A 2 OPEN B 3 STOP 4 CLOSE ESC TO EXIT From the time of its installation the 460P counts the number of cycles performed by the automation to give an idea of its degree of usage...

Страница 16: ...nfiguration on the card it can be loaded from this menu Select option 1 Load 460P standard configuration resident in the FAACTOTUM 2 Ignore the question and proceed 1 F1 2 F2 SELECT MODE 14 1 F1 2 F2...

Страница 17: ...time as the Gatecoder and vice versa 5 With the sole exception given below it is not possible to assign the same function to more than one terminal 6 The 460P card terminal IN2 can also be configured...

Страница 18: ...XXXXXX 60Hzmainspowersupply 30 XXXXXXX0 FAILSAFEoninputFSW CLdisabled disabled XXXXXXX1 FAILSAFEoninputFSW CLenabled XXXXXX0X FAILSAFEoninputFSW OPdisabled disabled XXXXXX1X FAILSAFEoninputFSW OPenabl...

Страница 19: ...mand The contact remains closed until the state is reset REG No VALUE FUNCTION DEFAULT 14 1001XXXX panicstateactivated 0000XXXX Default standardwarninglightfunction 3 Automation open state contact The...

Страница 20: ...ds 14 11 ELECTRIC LOCK ACTIVATION TIME Sets the duration of electric lock activation Thesetvaluemustbelowerthantheopeningandclosingleaf delay times REG No VALUE FUNCTION DEFAULT 56 seconds electric lo...

Страница 21: ......

Страница 22: ......

Отзывы: