background image

8.4

TIME LEARNING

go to 

“8.5   ADVANCED PROGRAMMING”

8.3

INPUT ASSIGNING

Card 460P and the input expansion module (MEI module) have a default terminal block input alloca-
tion, which is the one given in the electronic control unit instructions.
However, with the exception of input 1 of the 460P (which represents the OPEN-A input and cannot be
changed), a different meaning can be assigned to the other available inputs in accordance with the
rules and limitations given in chapter 12 “Input management” in this manual.

Time learning serves to determine the working and deceleration times of each leaf.
As the motors are activated during this phase, it is advisable to check beforehand that the automation
works correctly (by running the “motor test” under the Diagnostics menu) and calibrate the by-pass
valves.
You can quit the learning cycle at any time (with consequent loss of the acquired times) by pressing the
ESC key, which takes you back to the beginning of the cycle.
N.B.:
1) The time learning cycle is displayed only if the FAACTOTUM is connected to the 460P control unit.
2) The “DECELERATE” option in the cycle menus appears only if Gatecoder is used, or if deceleration by
time is used.
3) When the limit switches are used, the “DECELERATE” option does not appear because the decelera-
tion start point is determined by the opening of the limit switch contact.
4) 

In the case of swing gates, the mechanical opening and closure stops are always necessary for

correct operation of the automation (even when the Gatecoder is used).

5) Leaf 1 is the leaf connected to motor M1; Leaf 2 is the leaf connected to motor M2.

8

ENTER

 This menu appears only if “NUMBER OF OPERATORS = 2” has previously been set.

When the 

ñ

 key is pressed, leaf 2 starts to close; when it is pressed again the leaf

stops closing and so on.
Each time the key is pressed, the arrow on the display moves to select the effect of
the subsequent pulse.

Close Leaf 2 completely and press ENTER.

(cont.)

ASSOCIATE CHOSEN
FUNCTION WITH INPUT
AND PRESS ENTER
INP.  2 =  XXXXXX

ENTER

INPUT MODULE?

  1->YES

   2  NO

1

F1

2

F2

C

à

When the 

ñ

 key is pressed, leaf 1 starts to close; when it is pressed again the leaf

stops closing and so on.
Each time the key is pressed, the arrow on the display moves to select the effect
of the subsequent pulse.

Close Leaf 1 completely and press ENTER.

ENTER

(cont.)

TIME LEARNING?

1->YES

   2  NO

2

F2

1

F1

ENTER

CLOSE LEAF 1

ñ

CLOSE
STOP
PRESS ENTER TO CONT.

CLOSE LEAF 2

ñ

CLOSE
STOP
PRESS ENTER TO CONT.

ENTER

The currently attributed function is shown for each available input (except for
inputs IN1 on the 460P and IN10-11 on the MEI module):
Press ENTER to confirm.
To modify, use 

ñ

 and  

ò

 to select the function you wish to assign to the input and

press ENTER.
Pressing the CLEAR key shows the input’s default function.
The input can also be disabled by selecting the “INACT” function.
All the inputs must be set in order to proceed to the subsequent menu.
When confirming each configured safety input (FSW-OP/CL, SAFE OP/CL), a menu
allows the Failsafe to be enabled or disabled.

 

Do not assign the same function to more than one inputs.

To skip the allocation cycle (and confirm the current settings), hold down the
SHIFT key and press the 

ò

 

key.

PG

PG

ENTER

CLEAR

SHIFT

Check whether the Input Expansion Module (MEI module) is installed in the 460P
card and select the corresponding option:
1 = MEI module installed
2 = MEI module not installed

Make the selection by moving the arrow-shaped cursor alongside the desired
option using the 

ï

 and 

ð

 keys and pressing ENTER, or key in the corresponding

number directly.

1

F1

2

F2

or

ENTER

+

Select option:
1 = Perform time learning cycle
2 = Do not perform time learning cycle and go to “Advanced programming”

1

F1

2

F2

or

ENTER

+

Make the selection by moving the arrow-shaped cursor alongside the desired
option using the 

ï

 and 

ð

 keys and pressing ENTER, or key in the corresponding

number directly.

Содержание FAACTOTUM

Страница 1: ...FAACTOTUM FAACTOTUM R...

Страница 2: ......

Страница 3: ...ms or it can be modified Besides programming the FAACTOTUM can be used to perform diagnostics and to check the operation of the automation and the connection to an external PC appropriate software pro...

Страница 4: ...rol unit 460P The FAACTOTUMcanbeconnectedtothepowerpackwiththe batteries fitted since the external power source is used preferentiallytosavebatterycharge The internal batteries operate as a buffer sup...

Страница 5: ...LP When enabled this key provides useful information regarding programming 8 SHIFT SHIFT Press this key to activate the alternative function of keys which have a double function e g alphanumeric keys...

Страница 6: ...his function prevents the FAACTOTUM from being used by anyone who does not know the password but it does not prevent access to the configuration saved on the 460P card Select the mode by moving the ar...

Страница 7: ...cter alphanumeric identification If you know the number enter it the corresponding identification will appear and press ENTER Alternatively pressing the and keys displays all the memory locations one...

Страница 8: ...uses a short closure movement before the leaves open to facilitateoperationoftheclosedpositionelectriclocks Selectoption 1 Inversion stroke enabled 2 Inversion stroke disabled 1 F1 2 F2 or ENTER Make...

Страница 9: ...through the logics avail able and their identifications When the desired logic appears press ENTER to select it If you know the location key in the number the identification appears and press ENTER o...

Страница 10: ...rrow on the display moves to select the effect of the subsequent pulse Close Leaf 2 completely and press ENTER cont ASSOCIATE CHOSEN FUNCTION WITH INPUT AND PRESS ENTER INP 2 XXXXXX ENTER INPUT MODULE...

Страница 11: ...eviously been set When the key is pressed Leaf 2 begins to close and the arrow on the display moves alongside the DECELERATION option When Leaf 2 has reached the position where you wish closing decele...

Страница 12: ...s for entering the register value DEC to enter the register value in decimal BIN to enter the register value in binary If DEC is selected enter the value using the number keys If BIN is selected press...

Страница 13: ...After entering the identification press ENTER to save and proceed If you select an occupied location saving will cause the resident configuration to be overwritten A K U C M W E O Y G Q I S B D F H J...

Страница 14: ...omplete diagnostics on the automation the FAACTOTUM must be connected to the 460P electronic control unit Press ENTER to continue ENTER The menus contained in the diagnostics with the exception of the...

Страница 15: ...IMPULSE COMMAND 1 OPEN A 2 OPEN B 3 STOP 4 CLOSE ESC TO EXIT From the time of its installation the 460P counts the number of cycles performed by the automation to give an idea of its degree of usage...

Страница 16: ...nfiguration on the card it can be loaded from this menu Select option 1 Load 460P standard configuration resident in the FAACTOTUM 2 Ignore the question and proceed 1 F1 2 F2 SELECT MODE 14 1 F1 2 F2...

Страница 17: ...time as the Gatecoder and vice versa 5 With the sole exception given below it is not possible to assign the same function to more than one terminal 6 The 460P card terminal IN2 can also be configured...

Страница 18: ...XXXXXX 60Hzmainspowersupply 30 XXXXXXX0 FAILSAFEoninputFSW CLdisabled disabled XXXXXXX1 FAILSAFEoninputFSW CLenabled XXXXXX0X FAILSAFEoninputFSW OPdisabled disabled XXXXXX1X FAILSAFEoninputFSW OPenabl...

Страница 19: ...mand The contact remains closed until the state is reset REG No VALUE FUNCTION DEFAULT 14 1001XXXX panicstateactivated 0000XXXX Default standardwarninglightfunction 3 Automation open state contact The...

Страница 20: ...ds 14 11 ELECTRIC LOCK ACTIVATION TIME Sets the duration of electric lock activation Thesetvaluemustbelowerthantheopeningandclosingleaf delay times REG No VALUE FUNCTION DEFAULT 56 seconds electric lo...

Страница 21: ......

Страница 22: ......

Отзывы: