REVERSING STROKE?
1-> YES
2 NO
1
F1
2
F2
8.2
LOGIC SELECTION
B
LOGIC : XXXXXXXX
1-> CURRENT
2
STANDARD
3
CUSTOMISED
SELECT LOGIC WITH
ñ
AND
ò
AND HIT ENTER
LOGIC: 1 XXXXXXXX
SET PAUSE TIME
T= xxx [0-255 sec]
ENTER
SET LEAF
OPENING DELAY:
T= xxx [0-255 sec]
ENTER
SET LEAF
CLOSURE DELAY:
T= xxx [0-255 sec]
ENTER
ENTER
8.3 ASSIGN INPUTS
(
cont.)
7
(cont.)
The inversion stroke causes a brief opening movement before the leaves close to
facilitate operation of the open position electric locks.
Select option:
1 = Enable inversion stroke
2 = Disable inversion stroke
1
F1
2
F2
or
ENTER
+
Make the selection by moving the arrow-shaped cursor alongside the desired
option using the
ï
and
ð
keys and pressing ENTER, or key in the corresponding
number directly.
This menu displays the currently used logic and provides the option of changing it
by selecting one of the logics contained in the FAACTOTUM memory:
1 = Maintain currently loaded logic
2 = Use preloaded standard logics (A, S, E, EP, P, B, C or B/C)
3 = Use customised logics created with advanced programming
1
F1
3
F3
2
F2
or
PG
PG
ENTER
+
Make the selection by moving the arrow-shaped cursor alongside the desired
option using the
ñ
and
ò
keys and pressing ENTER, or key in the corresponding
number directly.
Each logic is represented by a number (01 to 16) indicating the memory location
and an alphanumeric identification (max. 8 characters).
To select a different logic, press the
ñ
and
ò
keys to scroll through the logics avail-
able and their identifications.
When the desired logic appears, press ENTER to select it.
If you know the location, key in the number (the identification appears) and press
ENTER.
or
1
6
2
7
3
8
4
9
5
0
F1
F2
F3
F4
F5
*
/
-
+
.
PG
PG
ENTER
+
➲
This menu appears only if an automatic logic has previously been selected.
Enter the pause time in seconds (permitted values in brackets) using the number
keys, then press ENTER.
1
6
2
7
3
8
4
9
5
0
F1
F2
F3
F4
F5
*
/
-
+
.
ENTER
+
➲
This menu appears only if “NUMBER OF OPERATORS = 2” has previously been
set.
With a single leaf this time is automatically set to zero.
The opening leaf delay is the time that elapses between opening activation of
motor M1 and that of motor M2 (delayed on opening).
Enter the opening leaf delay time in seconds (permitted values in brackets)
using the number keys, then press ENTER.
When a closed position electric lock is used on each leaf, the set delay must be
longer than the electric lock activation time (standard 1 s).
1
6
2
7
3
8
4
9
5
0
F1
F2
F3
F4
F5
*
/
-
+
.
ENTER
+
➲
This menu appears only if “NUMBER OF OPERATORS = 2” has previously been
set.
With single leaf operation this time is automatically set to zero.
The closure leaf delay is the time that elapses between closure activation of
motor M2 and that of motor M1 (delayed on closing).
Enter the closure leaf delay time in seconds (permitted values in brackets)
using the number keys, then press ENTER.
When a closed position electric lock is used on each leaf, the set delay must be
longer than the electric lock activation time (standard 1 s).
1
6
2
7
3
8
4
9
5
0
F1
F2
F3
F4
F5
*
/
-
+
.
ENTER
+
1
F1
2
F2
3
F3