ATTUATORE ELETTROMECCANICO 230V IRREVERSIBILE A
CREMAGLIERA PER CANCELLI SCORREVOLI FINO A 2200 KG
DI PESO

230V ELECTRO-MECHANICAL IRREVERSIBLE RACK
ACTUATOR FOR SLIDING GATES UP TO 2200 KG

OPERATEUR ELECTROMECANIQUE 230V IRREVERSIBLE A
CREMAILLERE POUR PORTAILS COULISSANTS JUSQU'A 
2200 KG DE POIDS

MOTOR ELECTROMECANICO 230V IRREVERSIBLES A
CREMALLERA PARA PUERTAS CORREDERAS HASTA 
2200 KG DE PESO

I

GB

F

E

FORTECO

IL n. 284-1
EDIZ. 04/07/2012

V2 S.p.A.

Corso Principi di Piemonte, 65/67

12035 RACCONIGI (CN) ITALY

tel. +39 01 72 81 24 11  -  fax +39 01 72 84 050

info@

gatestore.co.uk

  -  www.

remotecontrolgates.co.uk

Содержание FORTECO

Страница 1: ...LECTROMECANIQUE 230V IRREVERSIBLE A CREMAILLERE POUR PORTAILS COULISSANTS JUSQU A 2200 KG DE POIDS MOTOR ELECTROMECANICO 230V IRREVERSIBLES A CREMALLERA PARA PUERTAS CORREDERAS HASTA 2200 KG DE PESO I...

Страница 2: ......

Страница 3: ...Y 35 BLINKER 35 COURTESY LIGHT 35 PHOTOCELLS 36 SAFETY RIBBONS 36 STOP 37 ACTIVATION INPUTS 37 PLUG IN RECEIVER 37 EXTERNAL AERIAL 38 ADI INTERFACE 38 ELECTRIC CONNECTIONS TABLE 38 CONTROL PANEL 40 US...

Страница 4: ...ans of a proper tool and adjusted according to the max limits which EN 12453 allows We recommend to make use of an emergency button to be installed by the automation connected to the control unit STOP...

Страница 5: ...A Full load current 3 A 3 2 A 4 A Running capacitor 12 F 18 F 18 F Start off capacitor 12 F 14 F 14 F Gate maximum speed 0 16 m s 0 16 m s 0 16 m s Maximum thrust 900 N 1300 N 1550 N Duty cicle ambie...

Страница 6: ...ated in the drawing for the foundations 2 Arrange for one or two pipes for the passage of electric cables 3 Assemble the 4 clamps on the anchoring plate and fix them with the 4 bolts issued with the m...

Страница 7: ...ame height than the motor pinion The rack MUST BE positioned 1 or 2 mm over the pinion of the motor all the gate length WARNING If the gate is very heavy we suggest to use an M4 22x22 rack code 162324...

Страница 8: ...rn clockwise until reached the limit switch To restore the automation proceed as follows 1 turn the key L anticlockwise until reached the limit switch then draw it out 2 turn the key K anticlockwise c...

Страница 9: ...otocells safety ribbons and triacs before each opening Deactivation of safety inputs through the configuration menu no jumper is required for terminals concerning safety devices that have not been ins...

Страница 10: ...king the proper working If using control units suited to the test by power outage connect the power supply cables of the control unit between terminals P13 and P14 of the control unit Otherwise connec...

Страница 11: ...closed and it will immediately stop as the contact is open Timer mode it is similar to the standard mode but the gate stays open completely or partially while the contact is closed on input as soon a...

Страница 12: ...ace interface of the control unit allows the connection to V2 optional modules Refer to V2 catalogue or to the technical sheets to see which optional modules with ADI interface are available for this...

Страница 13: ...ENGLISH 39 PROGRAMMING WHEEL F1 10A...

Страница 14: ...ial configuration menu accessible and explorable by means of the small wheel on the right side of the display allows programming the functions and times of the control unit WARNING Outside the configu...

Страница 15: ...e correct position mCAUTION to perform the self learning procedure it is necessary to disable the ADI interface by means of the menu i Adi If some safeties are controlled by means of the ADI module th...

Страница 16: ...operations are required for more then a minute the control unit exits from the programming mode without saving the given information and changes will be lost Keeping the wheel pushed downwards the con...

Страница 17: ...in the closing phase In case there is an obstacle or the end of stroke operates the control unit can stop the opening phase before the relevant time expires To avoid that the gate does not close compl...

Страница 18: ...ower is gradually increased until reached the set value or 100 if the take off is enabled Higher is the set value longer the length of time of the ramp that is the time necessary to reach the value of...

Страница 19: ...e slowing down function in order to measure both opening and closing times and to enable it again once the setup has been carried out The control unit will automatically consider the working time dela...

Страница 20: ...n with the opening phase command is ignored mWARNING a Start command in any phase of partial opening will cause the total opening the Start Pedestrian command is always ignored during a total opening...

Страница 21: ...ng the opening cycle of the gate t LUC the relay is enabled at the receiving of a control of start or pedestrian start choosing this option a submenu is entered it allows to set the length of the acti...

Страница 22: ...en as long as the Start input stays closed and it will close as long as Pedestrian Start stays closed oroL Timer operation the gate stays open while the Start input or Pedestrian Start input is closed...

Страница 23: ...te starts moving Otherwise it will stand still and the flashing light will stay onfor 5 sec The whole test cycle lasts less than one second mWARNING V2 suggests to keep activated the test of the photo...

Страница 24: ...m test enabled mWARNING V2 suggests to keep activated the test of the photocells in order to grant a higher safety of the system Encoder Input The PD18 control unit allows connection of the encoder in...

Страница 25: ...is disabled the reverse manoeuvre lasts until the gate reaches the limit switch End of Programming This menu allows to finish the programming both default and personalized saving the modified data int...

Страница 26: ...ou can alternate the display of thousands or units Area 2 is the reading of the number of cycles before the next request for service its value is rounded down to the hundreds Area 3 is the setup of th...

Страница 27: ...ning it means that the setup cycle count down expired and the control unit shows that service is required OPERATION DEFECTS This paragraph shows some possible operation defects along with their cause...

Страница 28: ...no Start command is not available ChiU Command close gate PAUS Stop the gate and goes in pause St Ch Start in closing StoP Stop Start command stop the gate APEr Start command open the gate St PA Star...

Страница 29: ...en the gate is still no Not available Ch Photocell is active during the closing Ft tE no Si Test of operating of the photocells no CoS1 Input safety edge 1 fix edge no no Non active input AP Input act...